Related Experiment Video
Updated: Feb 2, 2026

Semi-Quantitative Analysis of Peptidoglycan by Liquid Chromatography Mass Spectrometry and Bioinformatics
Published on: October 13, 2020
Evolving window factor analysis-multivariate curve resolution with automated library matching for enhanced peak
Jeffrey A Cramer1, Mark H Hammond1, Thomas N Loegel1
1Naval Research Laboratory, Code 6181, 4555 Overlook Ave. SW, Washington, DC, 20375, USA.
Abstract:
Fuel chromatography is inherently limited by the high complexity of petroleum fuel compositions. In practice, almost no fuel components are fully resolved in gas chromatography. This is due to both insufficient peak capacity for the large number of individual components within time and chromatographic efficiency constraints, and insufficient resolving power of the stationary phase in the gas chromatography column relative to the many structurally similar isomers or homologs present in petrochemical fuels. Multidimensional approaches, longer columns and slower heating rates can offer some benefits but will not necessarily fully resolve co-eluting fuel compounds, especially within reasonable analysis times. The following work details how deconvolved mass spectral loadings, combined with library matching, provide a quality metric against which to automatically evaluate results obtained from an experimental evolving window factor analysis-multivariate curve resolution deconvolution algorithm applied to gas chromatography-mass spectrometry data. This algorithm was evaluated in the context of trace component detection in synthetic fuel data sets, dodecane and tetradecane detection in petrochemical fuels, and the detection of natural products unlikely to be present in petrochemical fuels. In the case of the trace component detection challenge, the experimental algorithm outperformed a control algorithm that utilized a singular value-based quality metric. Meanwhile, when detecting dodecane, tetradecane, and natural products in petrochemical fuels, the experimental algorithm allowed for higher-quality compound identification results than could be obtained without peak deconvolution, thus reliably improving fuel component resolution in an automated fashion.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
High-Resolution Mass Spectrometry (HRMS)
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II