Related Experiment Video
Updated: Feb 2, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Comparison of Cohesive Models in EDEM and LIGGGHTS for Simulating Powder Compaction
Cristina Ramírez-Aragón1, Joaquín Ordieres-Meré2,3, Fernando Alba-Elías4
1Department of Mechanical Engineering, University of La Rioja, C/Luis de Ulloa, 20, 26004 Logroño, Spain. maria-cristina.ramirez@alum.unirioja.es.
Abstract:
The purpose of this work was to analyse the compaction of a cohesive material using different Discrete Element Method (DEM) simulators to determine the equivalent contact models and to identify how some simulation parameters affect the compaction results (maximum force and compact appearance) and computational costs. For this purpose, three cohesion contact models were tested: linear cohesion in EDEM, and simplified Johnson-Kendall-Roberts (SJKR) and modified SJKR (SJKR2) in LIGGGHTS. The influence of the particle size distribution (PSD) on the results was also investigated. Further assessments were performed on the effect of (1) selecting different timesteps, (2) using distinct conversion tolerances to export the three-dimensional models to standard triangle language (STL) files, and (3) moving the punch with different speeds. Consequently, we determined that a timestep equal to a 10% Rayleigh timestep, a conversion tolerance of 0.01 mm, and a punch speed of 0.1 m/s is adequate for simulating the compaction process using the materials and the contact models in this work. The results showed that the maximum force was influenced by the PSD due to the rearrangement of the particles. The PSD was also related to the computational cost because of the number of simulated particles and their sizes. Finally, an equivalence was found between the linear cohesion and SJKR2 contact models.
Related Concept Videos
Cohesion
On a...
Compact Bone
Compact bone, also called cortical bone, is the denser, stronger of the two types of bone tissue. It is found under the periosteum and in the diaphyses of long bones, where it provides support and protection. The microscopic structural unit of compact bone is called an osteon, or haversian system. Each osteon is composed of concentric rings of calcified...
Compacting Factor test
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...

