Brain CT and MRI medical image fusion using convolutional neural networks and a dual-channel spiking cortical model
Ruichao Hou1, Dongming Zhou2, Rencan Nie1
1Information College, Yunnan University, Kunming, 650504, China.
Abstract:
The aim of medical image fusion is to improve the clinical diagnosis accuracy, so the fused image is generated by preserving salient features and details of the source images. This paper designs a novel fusion scheme for CT and MRI medical images based on convolutional neural networks (CNNs) and a dual-channel spiking cortical model (DCSCM). Firstly, non-subsampled shearlet transform (NSST) is utilized to decompose the source image into a low-frequency coefficient and a series of high-frequency coefficients. Secondly, the low-frequency coefficient is fused by the CNN framework, where weight map is generated by a series of feature maps and an adaptive selection rule, and then the high-frequency coefficients are fused by DCSCM, where the modified average gradient of the high-frequency coefficients is adopted as the input stimulus of DCSCM. Finally, the fused image is reconstructed by inverse NSST. Experimental results indicate that the proposed scheme performs well in both subjective visual performance and objective evaluation and has superiorities in detail retention and visual effect over other current typical ones. Graphical abstract A schematic diagram of the CT and MRI medical image fusion framework using convolutional neural network and a dual-channel spiking cortical model.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Convolution Properties II
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...
Imaging Studies for Cardiovascular System V: CT
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Convolution Properties I
The commutative property reveals that the input and the impulse response of an LTI (Linear Time-Invariant) system can be interchanged without affecting the output:
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT