Javed Hussain Farooqui1, Arpan Gandhi1, Umang Mathur1
1Dr. Shroff's Charity Eye Hospital, Kedarnath Marg, Daryaganj, New Delhi, India.
Purpose:
To evaluate the cause of clusters of increased postoperative anterior chamber inflammation after uneventful cataract surgery, and to examine its relation to the presence of endotoxins in sterile consumables.
Setting:
Tertiary eye center in north India.
Design:
Single-center retrospective case series.
Methods:
All cataract surgeries performed at the tertiary eye center over 12 weeks (October 1, 2017 to December 31, 2017) were noted. Any patient with a "severe reaction" postoperatively was monitored closely and the postoperative drug regimen was altered accordingly. "Severe reaction" was defined as any patient with more than 4+ cells and/or fibrin with or without hypopyon. The Hospital Infection Control committee was informed, and a root cause analysis was performed to determine the cause. All the consumables were recalled and replaced. The samples were sent for microbiological evaluations.
Results:
Of the 781 cataract surgeries performed, 81 patients had a severe reaction. Most patients were men (71%) and the mean age of the patients was 63 years. Twelve patients had fibrin, 3 of whom presented with hypopyon. Because all samples were negative of any growth, endotoxin tests were performed. All the samples were found to be negative, except for the ophthalmic viscosurgical device (OVD), which showed positive endotoxin levels. The OVD was changed and the anterior chamber reactions ceased to occur.
Conclusion:
A careful, stepwise approach is necessary when investigating clusters of increased postoperative anterior chamber reactions after uneventful surgery. A high degree of suspicion is important to rule out all possible reasons and in the absence of any identifiable cause, sterile consumables should be checked for endotoxins.
More Related Videos
05:27Author Spotlight: Harnessing Mouse Eye Chambers for Noninvasive Liver Spheroid Studies
Published on: March 29, 2024
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
Related Concept Videos
Inflammation
Secondary Active Transport
Quantifying Heat
Responses to Heat and Cold Stress
Specific Heat
For example, increasing the temperature of one gram of water by 1°C requires one calorie of heat energy and can be written as 1 cal/g-°C, or...
Secondary Healthcare System