Image Quality of ECG-Triggered High-Pitch, Dual-Source Computed Tomography Angiography for Cardiovascular Assessment
Christian A Barrera1, Hansel J Otero2, Ammie M White2
1Department of Radiology, The Children's Hospital of Philadelphia, Philadelphia, PA..
Purpose:
Evaluate the feasibility and determinants of image quality of ECG-triggered High-Pitch Dual-Source Computed Tomography Angiography (CTA) for cardiovascular assessment in Children.
Material And Methods:
All children that underwent ECG-triggered High-Pitch Dual-Source CTA between August 2014 and September 2017 were identified. Scanner parameters and patients' information were retrieved. Objective image quality was evaluated measuring the Hounsfield units (HU) and standard deviation of regions of interests in the left ventricle, ascending and descending aorta. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Qualitative image quality was recorded independently by two pediatric radiologist blinded using a three-point scale: 1 - good image quality, 2 - mild artifacts, 3 - poor image quality. Continuous variables were presented as mean ± standard deviation. The interobserver agreement and non-parametric test were used.
Results:
93 patients (mean age 5.6 ± 7.1 years) were selected. Average cardiovascular attenuation, SNR and CNR were 406.2 ± 146.3 HU, 24.2 ± 16.0 HU and 52.1 ± 38.6 HU, respectively. Average image quality was 1.51 ± 0.48 and the inter-observer agreement was excellent (k = 0.8). Worse subjective quality scores were associated with lower age, height, weight, BSA, lower contrast dose and slower injection rates (p < 0.05). Higher heart rate was associated with high attenuation (p < 0.05), however, SNR and CNR did not show an association with heart rate (p = 0.80).
Conclusions:
ECG-triggered High-Pitch Dual-Source cardiac CTA is feasible and provides good or excellent image quality for the evaluation of cardiovascular diseases in children.
More Related Videos
09:23Author Spotlight: Enhancing Transplantation Research Through MicroCT Angiography in Murine Models
Published on: September 22, 2023
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...