Toxicity effects of the organic UV-filter 4-Methylbenzylidene camphor in zebrafish embryos

Carla Quintaneiro1, Bruna Teixeira1, Juan L Benedé2

  • 1Department of Biology & CESAM, University of Aveiro, 3810-193, Aveiro, Portugal.

Chemosphere
|November 26, 2018
PubMed

Related Concept Videos

Development of the Sexual Organs in the Embryo and Fetus01:15

Development of the Sexual Organs in the Embryo and Fetus

Development of the reproductive organs in an embryo starts from a bipotential state. This means the early embryo can develop either male or female reproductive organs. The formation of these organs begins with the growth of gonadal ridges that arise from the intermediate mesoderm during the fifth week of development.
Near the gonadal ridges, two duct systems are present: the mesonephric ducts (Wolffian ducts) and paramesonephric ducts (Müllerian ducts). These ducts form the basis for the...
3.7K
Passive Filters01:27

Passive Filters

Passive filters are utilized to shape the frequency spectrum of signals across a diverse array of applications. These filters, using only passive elements like resistors (R), inductors (L), and capacitors (C), are capable of selectively allowing or blocking certain frequency ranges without the need for external power sources.
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
1.0K
Active Filters01:25

Active Filters

Active filters are electronic circuits that use operational amplifiers (op-amps), resistors, and capacitors to filter out unwanted frequency components from a signal. A first-order low-pass active filter is designed to pass signals with a frequency lower than a certain cutoff frequency and attenuate frequencies higher than that cutoff frequency. The transfer function for a first-order low-pass active filter is:
1.3K
UV–Vis Spectrum01:30

UV–Vis Spectrum

When light passes through a substance, a portion of the light is absorbed while the remaining light is reflected or transmitted. If the molecule absorbs light between the wavelengths of 180–400 nm range, the UV spectrum is obtained, and if it absorbs light in the 400–780 nm wavelength range, the visible spectrum is obtained.     
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
2.1K
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
3.6K
Toxic Reactions: Overview01:26

Toxic Reactions: Overview

When toxic substances penetrate the human body, they disseminate to various tissues, undergoing metabolic changes. This process yields reactive metabolites that may covalently bind with specific target molecules, resulting in toxicity.
Toxicity falls into two primary categories: local and systemic.
Local toxicity appears at the exposure site, such as protein denaturation caused by caustic substances.
In contrast, systemic toxicity requires the toxic agent's absorption and distribution,...
2.0K