Related Experiment Video
Updated: Feb 2, 2026

A Lightweight, Headphones-based System for Manipulating Auditory Feedback in Songbirds
Published on: November 26, 2012
Low reversed cyclic loading tests for integrated precast structure of lightweight wall with single-row reinforcement
Jia Suizi1, Cao Wanlin2, Zhang Yuchen3
1China University of Geosciences (Beijing), School of Engineering and Technology, No. 29, Xueyuan Road, Haidian District, Beijing 100083, People's Republic of China.
Abstract:
Given the development of precast structures for low-rise residential buildings, this study explores a new structure-namely, an integrated precast structure of lightweight recycled concrete wall with single-row reinforcement-under a lightweight steel frame filled with recycled concrete (integrated precast structure for short). The lightweight steel frame and lightweight wall cooperate to bear the forces. The applied concealed bracing, either a rebar bracing or a steel plate bracing, increases the shear resistance of the wall. The lightweight steel frame is designed to bear the vertical loading, whereas the seismic load in the horizontal direction is jointly borne by the frame and wall. This study presents the results of low reversed cyclic loading tests on nine specimens of integrated precast structures. An analysis is then carried out to investigate the mechanical properties of the specimens; based on these results, a formula for the force-bearing performance of the inclined section is developed. The results show satisfactory performance as an integrated piece; the proposed structure has two seismic lines of defence, with the lightweight wall restraint by the side frame being the first line and the steel frame being the second line. Because the failure of the wall can be categorized as shear failure, the restraint of the lightweight steel frame significantly reduces the potential damage of the wall. As the beams and columns of the steel frame tend to bend against failure, the wall filling helps resist sliding. Therefore, the reinforced joints of the connecting beams and columns show no visible signs of damage, indicating that the connection between the beams and columns is reliable. The narrow spacing of rebars and the setting of concealed bracing contribute to the increase in ductility and energy efficiency of the integrated structure and the evident reduction in the failure process. Furthermore, the recycled concrete increases the seismic resistance of the structure.
Related Concept Videos
Unsymmetric Loading of Thin-Walled Members
The concept of the shear center is crucial in countering the...
Structural Steel Products
Once shaped, the steel's final form emerges as a continuous length, which is then segmented by a hot saw into manageable pieces. These segments...
Unsymmetric Loading of Thin-Walled Members: Problem Solving
To compute the shear forces, find the shear flow at a specific distance from the endpoint using the vertical shear and the moment of inertia values. The total shear force on the flange is calculated by integrating the shear flow from one end of the flange to the other.
Next, calculate the moments of...
Load along a Single Axis
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
Framing Effects
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...