Related Experiment Video
Updated: Feb 2, 2026

A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
Published on: January 6, 2023
Internal Fixation of Posterior Pelvic Ring Injuries Using Iliosacral Screws in the Dysmorphic Upper Sacrum
Saam Morshed1, Kevin Choo1, Utku Kandemir1
1Orthopaedic Trauma Institute, University of California, San Francisco, 2550 23rd Street, Building 9, 2nd Floor, San Francisco, CA 94110.
Introduction:
The correct usage of preoperative and intraoperative imaging allows fixation of posterior pelvic ring injuries with safely positioned iliosacral screws in the setting of sacral dysmorphism.
Step 1 Preoperative Planning:
Obtain CT reformats along the longitudinal axis of the sacrum to determine the orientation and diameter of the osseous corridor for selection of the ideal screw size, length, and trajectory.
Step 2 Patient Positioning:
Proper positioning enables reduction and accurate iliosacral screw placement.
Step 3 Fracture Reduction:
Reduction of the posterior pelvic ring confers stability; if closed reduction is unsuccessful, proceed with open reduction.
Step 4 Identification Of The Entry Point:
The entry point for an iliosacral screw into the upper sacral segment of a dysmorphic pelvis lies more posterior and caudal on the outer table of the posterior ilium than does a transsacral screw; adjust the entry point on the basis of inlet and outlet fluoroscopic views.
Step 5 Drilling Technique:
Insert a stout cannulated drill bit of 4.5 to 5 mm (depending on the core diameter of the intended iliosacral screw) over the Kirschner wire and drill it into the sacral body under fluoroscopic guidance, in accordance with the preoperative plan.
Step 6 Screw Insertion:
With the guidewire in the ideal position, measure the screw length off the inserted guidewire and advance a tap into the pathway; insert the screw and verify its position on the inlet, outlet, and lateral sacral views.
Results:
Understanding the three-dimensional anatomy of the posterior pelvic ring is essential to successful reduction and fixation of unstable pelvic injuries with use of percutaneous iliosacral screws.IndicationsContraindicationsPitfalls & Challenges.
More Related Videos
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Internal Energy
Internal Receptors
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...