Purpose:
Macrovascular endothelial function is commonly assessed using flow-mediated dilation (FMD) and is nitric oxide (NO) dependent. However, the vasoreactivity to low flow during the FMD protocol may complement FMD interpretation. This study aimed to investigate in adolescents: (1) the day-to-day reliability of low-flow-mediated constriction (L-FMC) and composite vessel reactivity (CVR); and (2) the relationship between L-FMC and FMD.
Methods:
A retrospective analysis of data on 27 adolescents (14.3 ± 0.6 year, 12 males) was performed. Participants had two repeat measures, on separate days, of macrovascular function using high-resolution ultrasound for assessment of L-FMC, FMD, and CVR.
Results:
On average, the L-FMC response was vasoconstriction on both days (-0.59 ± 2.22% and -0.16 ± 1.50%, respectively). In contrast, an inconsistent response to low flow (vasoconstriction, dilation, or no change) was observed on an individual level. Cohen's Kappa revealed poor agreement for classifying the L-FMC measurement between visits (k = 0.04, P > .05). Assessment of the actual vessel diameter was robust with a coefficient of variation of 1.7% (baseline and peak) and 2.7% (low-flow). The between-day correlation coefficient between measures was r = .18, r = .96 and r = .52 for L-FMC, FMD, and CVR, respectively. No significant correlation between FMD and L-FMC was observed for either visit (r = -.06 and r = -.07, respectively; P > .05).
Conclusion:
In adolescents, the low-flow vasoreactivity is inconsistent between days. Whereas the actual vessel diameter is reproducible, the measurement of L-FMC and CVR has poor between-day reliability compared to FMD. Finally, L-FMC, and FMD are not significantly correlated.
More Related Videos
09:40Ultrasound Assessment of Flow-Mediated Dilation of the Brachial and Superficial Femoral Arteries in Rats
Published on: November 3, 2016
08:42Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Reliability and Validity
Cognitive Development During Adolescence
Distribution Reliability and Automation
Erikson's Theory on Socioemotional Development during Adolescence