Related Experiment Video
Updated: Feb 2, 2026

Standardized Modular Assembly of Polycistronic Operons with Modular Cloning (MoClo) using the In-Cloning toolkit
Published on: September 2, 2025
Complications following 250 cemented modular hip hemiarthroplasties
1Department of Orthopaedics and Traumatology, Turku University Hospital, Turku, Finland.
Background And Aims:
Hemiarthroplasty is a common method of treating displaced femoral neck fractures, especially among elderly non-active patients with frailty syndrome. Complications arising from the use of a modern, modular hemiendoprosthesis via a posterior approach have been poorly reported in this population. The aim of this study was to evaluate complications and mortality associated with the use of Lubinus sp II cemented, unipolar hemiarthroplasty prosthesis and posterior approach during a 9-year follow-up.
Material And Methods:
All patients (244) who received hemiarthroplasty due to an acute fracture of the femoral neck in Central Finland Hospital, Jyvaskyla, Finland, during 2007 and 2008 were included. Patient records were retrospectively reviewed for intraoperative and postoperative complications.
Results And Conclusion:
Women composed 70% (n = 171) of the study population. Mean age was 83 years for women and 80 years for men. A total of 31 (12%) complications were found in 30 patients. These were 12 dislocations (5% of all patients), 5 (2%) periprosthetic fractures, 2 (0.8%) superficial and 5 (2%) deep infections, 1 (0.4%) protrusion of the prosthesis, 2 (0.8%) intraoperative fractures, and 2 (0.8%) partial sciatic nerve palsies. Conversion to total hip replacement was performed in 9 cases (4%) and a reoperation was required in 15 (6%) cases. Mortality rate at 9 years was 78% (95% confidence interval = 72%-83%). The overall rate of complications was acceptable although mortality was high in this comorbid patient population. The need for conversion to total hip arthroplasty and reoperation is low.
More Related Videos
Related Concept Videos
Hydration of Cement
Soundness of Cement
Portland Cement
Fineness of Cement
Direct...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...

