Related Experiment Video
Updated: Feb 2, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Simultaneous motion monitoring and truth-in-delivery analysis imaging framework for MR-guided radiotherapy
Nikolai J Mickevicius1, Xinfeng Chen1, Zachary Boyd2
1Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI, United States of America.
Abstract:
Intrafraction motion (i.e. motion occurring during a treatment session) can play a pivotal role in the success of abdominal and thoracic radiation therapy. Hybrid magnetic resonance-guided radiotherapy (MR-gRT) systems have the potential to control for intrafraction motion. Recently, we introduced an MRI sequence capable of acquiring real-time cine imaging in two orthogonal planes (SOPI). We extend SOPI here to permit dynamic updating of slice positions in one-plane while keeping the other plane position fixed. In this implementation, cine images from the static plane are used for motion monitoring and as image navigators to sort stepped images in the other plane, producing dynamic 4D image volumes for use in dose reconstruction. A custom 3D-printed target, designed to mimic the pancreas and duodenum and filled with radiochromic FXG gel, was interfaced to the dynamic motion phantom. 4D-SOPI was acquired in a dynamic motion phantom driven by an actual patient respiratory waveform displaying amplitude/frequency variations and drifting and in a healthy volunteer. Unique 4D-MRI epochs were reconstructed from a time series of phantom motion. Dose from a static 4 cm × 15 cm field was calculated on each 4D respiratory phase bin and epoch image, scaled by the time spent in each bin, and then rigidly accumulated. The phantom was then positioned on an Elekta MR-Linac and irradiated while moving. Following irradiation, actual dose deposited to the FXG gel was determined by applying a R 1 versus dose calibration curve to R 1 maps of the phantom. The 4D-SOPI cine images produced a respiratory motion navigator that was highly correlated with the actual phantom motion (CC = 0.9981). The mean difference between the accumulated and measured dose inside the target was 4.4% of the maximum prescribed dose. These initial results demonstrate that 4D-SOPI is a promising imaging framework enabling simultaneous real-time motion monitoring and truth-in-delivery analysis for integrated MR-gRT systems.
Related Concept Videos
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Relative Motion Analysis - Acceleration
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...

