A field amplification enhanced paper-based analytical device with a robust chemiluminescence detection module
Xiu-Xiu Zhang1, Jia-Juan Liu1, Yu Cai1
1Research Center for Analytical Sciences, Chemistry Department, College of Sciences Northeastern University, Wenhua Road 3-11, Shenyang, 110819, Liaoning, China. zywu@mail.neu.edu.cn.
Abstract:
A sensitive detection method combined with an effective on-line concentration may improve the analytical performance of a paper-based analytical device (PAD), and its merits of low cost and portability in POCT are fully demonstrated. Here, a sensitive PAD system with chemiluminescence (CL) detection and electrokinetic preconcentration was introduced, and the performance was demonstrated by the detection of hemin. A commercially available low cost and miniaturized optical detection module was used for the CL detection. Firstly, hemin was stacked on a simple paper fluidic channel based on field amplified stacking (FAS), and then a CL reagent (luminol-H2O2) was loaded on the stacked band to initiate the CL reaction. The photons were directly detected using the detection module. With optimization of the background electrolyte (BGE), voltage and CL reagent, a limit of detection (LOD) of 0.58 nM for hemin was obtained with a linear range of 1-1000 nM (R2 = 0.995). With FAS, the signal intensity was about 13-fold enhanced. This PAD also exhibited satisfactory selectivity over possible interfering components at a 104 times higher concentration. The applicability of the PAD was demonstrated by the detection of hemin from iron supplements and human serum samples. With total manual operation, recovery rates of 84.8-115.6% were obtained with an RSD of less than 14.3%. With the introduction of the optical detection model, and together with FAS, both the LOD and dynamic range of this PAD were effectively improved.
Related Concept Videos
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
Development of Analytical Methods
Analyte Adsorption and Distribution
Jung's Analytical Theory
Self-Evaluation: Self-Enhancement and Self-Verification
Graphical and Analytic Representation of Sinusoids
The first step is measuring the peak-to-peak value, which is twice the amplitude of the sinusoid. This provides information about the maximum voltage swing of the waveform.
Secondly, the period and angular frequency are determined. The period is the time taken for one complete cycle of the waveform, while...