Related Experiment Video
Updated: Feb 2, 2026

Computer-Aided Three-Dimensional Visualization in the Treatment of Locally Advanced Thyroid Cancer
Published on: June 9, 2023
Validation and comparison of three newly-released Thyroid Imaging Reporting and Data Systems for cancer risk
Ting Xu1, Ya Wu2, Run-Xin Wu3
1Department of Endocrinology, Jiangsu Province Official Hospital, Nanjing, China.
Purpose:
To validate and compare diagnostic value of three newly-released Thyroid Imaging Reporting and Data Systems (TIRADS) for cancer risk determination.
Methods:
Total 2031 patients with 2465 thyroid nodules were recruited for this study. Ultrasound (US) images were categorized based on three TIRADS editions established by Korean Society of Thyroid Radiology (KSThR), European Thyroid Association (ETA) and American College of Radiology (ACR). ROC curves were established to compare diagnostic value.
Results:
Total 1460 benign and 1005 malignant nodules were enrolled. The malignancy rates of each category in KSThR-TIRADS were 2.8%, 5.1%, 33.7% and 79.6%, respectively. For European-TIRADS, 0, 3.1, 22.8, and 73.5% of nodules categorized as 2 to 5 were malignant. Distribution of carcinomas among ACR-TIRADS categories was 0%, 2.3%, 7.5%, 40.1% and 81.4%, respectively. In terms of diagnostic value, KSThR-TIRADS had highest AUC (0.855) and specificity (87.4%), while lowest (71.4%) sensitivity. ACR-TIRADS showed best sensitivity (96.6%) with lowest specificity (52.9%) and the AUC (0.846) was slightly lower than KSThR-TIRADS. Total 56.1, 45.4, and 37.4% fine-needle aspiration biopsy (FNAB) were recommended by KSThR, ETA and ACR, revealing 42.8%, 44.5% and 53.6% malignant lesions, respectively. The rate of unnecessary FNAB was lowest with the ACR (17.3%), followed by ETA (25.2%) and KSThR (32.1%).
Conclusion:
All these US models showed great value in predicting thyroid malignancy. Among them, KSThR-TIRADS showed the most effective diagnostic performance in specificity, while ACR-TIRADS yielded best sensitivity. As for FNAB criteria, ACR-TIRADS showed the lowest rate of unnecessary FNAB and highest rate of malignancy in FNAB.
Related Concept Videos
Data Reporting and Recording
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
In Vitro Drug Release Testing: Overview, Development and Validation
Reliability and Validity
One-Compartment Open Model: Urinary Excretion Data and Determination of k