Related Experiment Video
Updated: Feb 2, 2026

Multimodal Hierarchical Imaging of Serial Sections for Finding Specific Cellular Targets within Large Volumes
Published on: March 20, 2018
A Comparison of Partial Volume Correction Techniques for Measuring Change in Serial Amyloid PET SUVR
Christopher G Schwarz1, Jeffrey L Gunter1,2, Val J Lowe1
1Department of Radiology, Mayo Clinic and Foundation, Rochester, MN, USA.
Abstract:
Longitudinal PET studies in aging and Alzheimer's disease populations rely on accurate and precise measurements of change over time from serial PET scans. Various methods for partial volume correction (PVC) are commonly applied to such studies, but existing comparisons and validations of these PVC methods have focused on cross-sectional measurements. Rate of change measurements inherently have smaller magnitudes than cross-sectional measurements, so levels of noise amplification due to PVC must be smaller, and it is necessary to re-evaluate methods in this context. Here we compare the relative precision in longitudinal measurements from serial amyloid PET scans when using geometric transfer matrix (GTM) PVC versus the traditional two-compartment (Meltzer-style), three-compartment (Müller-Gärtner-style), and no-PVC approaches. We used two independent implementations of standardized uptake value ratio (SUVR) measurement and PVC (one in-house pipeline based on SPM12 and ANTs, and one using FreeSurfer 6.0). For each approach, we also tested longitudinal-specific variants. Overall, we found that measurements using GTM PVC had significantly worse relative precision (unexplained within-subject variability ≈4-8%) than those using two-compartment, three-compartment, or no PVC (≈2-4%). Longitudinally-stabilized approaches did not improve these properties. This data suggests that GTM PVC methods may be less suitable than traditional approaches when measuring within-person change over time in longitudinal amyloid PET.
Related Concept Videos
Work Done During Volume Change
Consider a gas confined to a cylinder fitted with a movable piston at one end. If the gas expands from volume V1 to volume V2, it exerts a force on the piston, such that the piston moves by a distance dr.
The work done by the gas on the piston can be expressed as
Le Chatelier's Principle: Changing Volume (Pressure)
Unsoundness of Aggregate due to Volume Change
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Distance Corrections
Serial Position Effect

