Related Experiment Video
Updated: Feb 2, 2026

Positron Emission Tomography Using 64-Copper as a Tracer for the Study of Copper-Related Disorders
Published on: April 28, 2023
Technical Note: Assessment of sampling technique from feeders for copper, zinc, calcium, and phosphorous analysis
Aaron M Jones1, Jason C Woodworth1, Christopher I Vahl2
1Department of Animal Sciences, College of Agriculture, Kansas State University, Manhattan, KS.
Abstract:
Diet treatments were arranged in a split-plot design with the whole-plot consisting of 1 of 6 concentrations of dietary Cu (22 to 134 mg/kg total Cu) and the subplot using 1 of 2 sampling techniques (probe vs. hand grab). A total of 6 feeders per treatment were sampled using a brass open handle probe. The probe was inserted into the feeder 4 times to obtain a 900 g of sample. The hand-collected samples were obtained by inserting a bare hand into the feeder approximately 8 times to obtain a 900 g of sample. Within a feeder and sampling technique, subsamples (200 g) were created by using a sample splitting device. In addition to the 6 individual feeder samples, a subsample (33 g) from each individual feeder was pooled within dietary treatment and sampling technique to form a single composite sample (200 g). This process was repeated until 4 individual composite samples were created for each diet and sampling technique. Next, all samples were ground through a centrifugal mill and submitted for mineral analysis in duplicate for Cu, Zn, Ca, and P analysis. Results indicated variability when sampling feeders with a probe were reduced (P = 0.013) for Cu and marginally reduced (P = 0.058) for Ca when compared with hand-sampling. However, no evidence for differences was detected among sampling techniques for Zn and P for the individual feeder analysis. When samples were pooled from 6 feeders to form a single composite sample, there was no evidence for differences detected among sampling techniques for Cu, Zn, Ca, and P analysis. From these results, sampling frequency calculations were determined to assess sampling accuracy within a 95% confidence interval. Results indicated that the number of feeders or composite samples required to analyze was less for Cu, Zn, Ca, and P analysis when using a probe compared with a hand sampling. In summary, sampling with a probe is associated with less variability on an individual sample basis, but when individual samples are pooled to form a composite sample, there was no evidence for difference among sampling techniques. Our results suggest samples collected for these analyses with a probe and composited would be the best option to minimize variation and analytical costs.
Related Concept Videos
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Skeleton and Calcium Homeostasis
Qualitative Analysis
For instance, group IV...
Roles of Electrolytes: Calcium and Phosphate
The calcium concentration in blood plasma is primarily...

