Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Alternative RNA Splicing02:18

Alternative RNA Splicing

25.2K
Alternative RNA splicing is the regulated splicing of exons and introns to produce different mature mRNAs from a single pre-mRNA. Unlike in constitutive splicing where a single gene produces a single type of mRNA, alternative splicing allows an organism to produce multiple proteins from a single gene and plays an important role in protein diversity.
There are five types of alternative RNA splicing that vary in the ways the pre-mRNA segments are removed or retained in the mature mRNA. The first...
25.2K
Alternative RNA Splicing02:18

Alternative RNA Splicing

5.1K
5.1K
Heart Valves01:16

Heart Valves

12.1K
The human heart is a complex organ with an intricate system of valves that regulate blood flow. There are two main types of valves: atrioventricular (AV) valves and semilunar valves.
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
12.1K
Null and Alternative Hypotheses01:16

Null and Alternative Hypotheses

12.7K
The actual hypothesis testing begins by considering two hypotheses. They are termed  the null hypothesis and the alternative hypothesis. These hypotheses contain opposing viewpoints.
The null hypothesis, denoted by H0 is a statement of no difference between the variables—they are not related. This can often be considered the status quo. As  a result if you cannot accept the null, it requires some action.
The alternative hypothesis, denoted by H1 or Ha, is a claim about the...
12.7K
Electric Generator: Alternator01:25

Electric Generator: Alternator

3.4K
Electric generators induce an emf by rotating a coil in a magnetic field. A simple alternator is an AC generator that creates electrical energy that varies sinusoidally with time. A simple alternator consists of a conducting loop that is placed inside a uniform magnetic field. The loop is connected to split rings connected to the external circuit with the help of brushes.
The magnetic flux passing through the coil varies sinusoidally as the loop rotates inside the magnetic field. This...
3.4K
Mitral Valve Prolapse I: Introduction01:27

Mitral Valve Prolapse I: Introduction

521
IntroductionThe mitral valve, one of the heart's four valves, regulates blood flow. These valves have flaps that open and close to direct blood properly through the heart and body. During each heartbeat, the flaps open for blood to pass through and seal shut to prevent backflow. Specifically, the mitral valve opens to allow blood flow from the heart's upper left chamber to the lower left chamber. It then closes securely as the lower left chamber contracts to pump blood to the body, preventing...
521

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Left atrial appendage exclusion during open cardiac surgery in patients without atrial fibrillation reduces 4-year ischemic stroke and mortality.

JTCVS structural and endovascular·2026
Same author

Long-term durability of bioprosthetic aortic valve replacement in young patients with bicuspid aortic stenosis.

JTCVS structural and endovascular·2026
Same author

Left and Right Heart Remodelling at 1 Year After Transcatheter Versus Surgical Aortic Valve Replacement: A Speckle-Tracking Echocardiography Study.

Interdisciplinary cardiovascular and thoracic surgery·2026
Same author

Postoperative 4-chamber cardiac function and outcomes following biatrial or left atrial Maze procedure for concomitant atrial fibrillation.

JTCVS open·2026
Same author

Artificial Intelligence Identification of Heart Failure With Preserved Ejection Fraction Substrate in Cardiac Surgery Patients.

Annals of thoracic surgery short reports·2026
Same author

Do Outcomes After Cardiac Surgery Differ by Preoperative Status and Socioeconomic Deprivation?

Annals of thoracic surgery short reports·2026

Related Experiment Video

Updated: Feb 2, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
14:14

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement

Published on: December 11, 2017

14.7K

Alternative Implantation Technique for Rapid Deployment Valve.

Yuji Kaku1, Romualdo J Segurola2, Alfredo Rego2

  • 1Department of Cardiac Surgery, Northwestern University Feinberg School of Medicine, Chicago, Illinois.

The Annals of Thoracic Surgery
|November 27, 2018
PubMed
Summary

This study introduces a streamlined implantation technique for the Edwards Intuity Elite rapid deployment valve, utilizing an automated suture fastener for enhanced efficiency and secure valve seating during cardiac surgery.

More Related Videos

Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
06:39

Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease

Published on: February 18, 2020

7.2K
Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
05:31

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model

Published on: June 8, 2022

3.4K

Related Experiment Videos

Last Updated: Feb 2, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
14:14

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement

Published on: December 11, 2017

14.7K
Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
06:39

Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease

Published on: February 18, 2020

7.2K
Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
05:31

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model

Published on: June 8, 2022

3.4K

Area of Science:

  • Cardiovascular Surgery
  • Medical Device Technology
  • Surgical Innovation

Background:

  • The Edwards Intuity Elite is a rapid deployment valve system used in aortic valve replacement.
  • Traditional implantation methods can be time-consuming and require specific techniques for secure valve placement.

Purpose of the Study:

  • To present a simplified and expedited method for implanting the Edwards Intuity Elite valve system.
  • To detail modifications in the final stages of valve deployment for improved efficiency and accuracy.

Main Methods:

  • Standard annular sizing and guiding suture placement.
  • Utilizing a vent catheter for improved valve exposure post-deployment.
  • Employing an automated suture fastening device for securing the valve, replacing traditional snares.
  • Visual confirmation of suture fastener placement for accurate valve seating.

Main Results:

  • The described method offers a simpler and faster implantation process.
  • The automated suture fastening device ensures secure valve seating with visual confirmation.
  • The technique aims to optimize the deployment of the Edwards Intuity Elite valve.

Conclusions:

  • This modified technique streamlines the implantation of the Edwards Intuity Elite valve.
  • The use of an automated suture fastener enhances procedural efficiency and valve fixation.