Reproducibility of Hemodynamic, Cardiac Autonomic Modulation, and Blood Flow Assessments in Patients with

Aluísio Andrade-Lima1, Marcel Chehuen1, Natan Silva Junior1

  • 1Exercise Hemodynamic Laboratory, School of Physical Education and Sport, University of São Paulo, São Paulo, Brazil.

Annals of Vascular Surgery
|November 27, 2018
PubMed

Insights

This study found that heart rate, blood pressure, and baseline blood flow measurements are reproducible in patients with intermittent claudication. However, vasodilatory responses showed poor reproducibility, indicating limitations for monitoring disease progression.

Area of Science:

  • Cardiovascular Physiology
  • Clinical Assessment
  • Peripheral Artery Disease Research

Background:

  • Peripheral artery disease (PAD) with intermittent claudication (IC) impacts patient mobility and quality of life.
  • Accurate and reproducible clinical assessments are crucial for monitoring disease progression and treatment efficacy in IC patients.

Purpose of the Study:

  • To evaluate the reproducibility of key physiological measurements in patients diagnosed with intermittent claudication.
  • To assess the reliability of heart rate (HR), blood pressure (BP), heart rate variability (HRV), and blood flow (BF) assessments.

Main Methods:

  • Twenty-nine IC patients underwent two test sessions 8-12 days apart.
  • Measurements included HR, BP, HRV (spectral analysis), and forearm/calf BF (strain gauge plethysmography).
  • Reproducibility was quantified using intra-class correlation coefficients (ICC) and coefficient of variation (CV).

Main Results:

  • Excellent reproducibility (ICC >0.8, CV <9%) was observed for HR and BP.
  • Most HRV measures (LFR-R, HFR-R) showed high reproducibility (ICC >0.9, CV <7%).
  • Baseline forearm and calf BF also demonstrated high reproducibility (ICC >0.9, CV <19%), while vasodilatory responses exhibited moderate to poor reproducibility.

Conclusions:

  • Systemic hemodynamics, cardiac autonomic function, and baseline blood flow assessments are highly reproducible in male IC patients.
  • The reproducibility of vasodilatory responses is limited, suggesting caution when using these measures for monitoring.
  • These findings support the use of reproducible measures for regular clinical monitoring of IC progression and intervention effects.
Abstract

Related Concept Videos

Blood Flow01:29

Blood Flow

Blood is pumped by the heart into the aorta, the largest artery in the body, and then into increasingly smaller arteries, arterioles, and capillaries. The velocity of blood flow decreases with increased cross-sectional blood vessel area. As blood returns to the heart through venules and veins, its velocity increases. The movement of blood is encouraged by smooth muscle in the vessel walls, the movement of skeletal muscle surrounding the vessels, and one-way valves that prevent backflow.
75.9K
Autoregulation of Blood Flow01:17

Autoregulation of Blood Flow

Autoregulation mechanisms are characterized by their inherent capacity for self-regulation without necessitating specific nervous stimulation or endocrine control. These mechanisms facilitate the adjustment of blood flow and, therefore, perfusion specific to each tissue region. This self-regulation encompasses chemical signals and myogenic controls.
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
8.1K
Applications of Integration to Find Blood Flow01:27

Applications of Integration to Find Blood Flow

Blood flow through a cylindrical blood vessel can be mathematically described using the principles of laminar flow, a regime in which fluid moves smoothly in parallel layers. In this model, the velocity of the blood is not uniform across the cross-section of the vessel; rather, it varies with the radial distance from the center. The maximum velocity occurs along the central axis, decreasing progressively toward the vessel walls, where it reaches zero due to viscous drag.Approximating Blood...
50
Blood Studies for Cardiovascular System I: Cardiac Biomarkers01:20

Blood Studies for Cardiovascular System I: Cardiac Biomarkers

Cardiac biomarkers are enzymes, proteins, and hormones released into the blood when cardiac cells are injured. They are powerful tools for triaging.
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
859
Autonomic Nervous System01:22

Autonomic Nervous System

The autonomic nervous system (ANS) is a critical component of the peripheral nervous system, primarily responsible for regulating involuntary bodily functions and maintaining homeostasis. It functions in tandem with the central nervous system (CNS) to seamlessly coordinate various physiological processes without the need for conscious control.
The ANS comprises two main divisions: the sympathetic and parasympathetic divisions. These divisions function antagonistically to maintain a dynamic...
12.8K
Assessing Blood pressure in the Leg01:11

Assessing Blood pressure in the Leg

Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
10.0K