Related Experiment Video
Updated: Feb 2, 2026

Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Minimally Invasive Sacroiliac Joint Fusion with Cylindrical Threaded Implants Using Intraoperative Stereotactic
Sharad Rajpal1, Sigita Burneikiene1
1Boulder Neurosurgical Associates; and Justin Parker Neurological Institute, Boulder, Colorado, USA.
Background:
Significant progress in hardware and surgical techniques for sacroiliac joint (SIJ) fusion surgeries has facilitated safer and more efficacious procedures for patients. Triangular-shaped implants for SIJ fusions are the most-studied devices and have demonstrated good short-term and long-term clinical outcomes. Reports on cylindrical threaded implants are very limited. Owing to biomechanical differences in the implants and the surgical techniques required for their placement, previously reported results may not be applicable to cylindrical threaded implants. The aim of this study was to report preliminary clinical experience with minimally invasive SIJ fusion using intraoperative stereotactic navigation and the Rialto SI Fusion System.
Methods:
We retrospectively reviewed 24 patients who underwent SIJ fusions between May 2015 and October 2017 performed by a single surgeon.
Results:
Mean total satisfaction score was 89.0% ± 27.6%. A statistically significant reduction (P = 0.0028) in low back pain scores was noted from an average baseline score of 6.6 ± 2.4 to 3.7 ± 3.3 postoperatively. Leg pain scores decreased from 4.8 ± 3.8 to 1.5 ± 2.9 (P = 0.0034). Mean surgical time was 53.0 ± 13.9 minutes. It took significantly longer (P = 0.0089) to perform the initial 13 cases (59.9 ± 15.2 minutes) compared with subsequent cases (45.4 ± 7.3 minutes). Estimated blood loss was minimal (10.4 ± 5.2 mL).
Conclusions:
Minimally invasive SI joint fusion using cylindrical threaded implants can be safely performed with minimal morbidity and good clinical outcomes.
Related Concept Videos
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Polar and Cylindrical Coordinates
Spherical and Cylindrical Capacitor
Conventionally, considering the symmetry, the electric field between the concentric shells of a spherical capacitor is directed radially outward. The magnitude of the field,...
Structural Joints: Synovial Joints
Inductance: Solid Cylindrical Conductor
Given the uniform current distribution, the magnetic field Hx and flux density Bx inside the conductor are...
Structural Joints: Fibrous Joints
Suture
All the bones of the skull, except for the mandible, are joined to each other by a fibrous joint called a suture. The fibrous connective tissue found at a suture strongly unites the adjacent skull bones and thus helps to protect the brain and form the face. In...