Related Experiment Video
Updated: Feb 2, 2026

Evaluation of Nanoparticle Uptake in Tumors in Real Time Using Intravital Imaging
Published on: June 21, 2011
Real-time CO2 uptake/emission measurements as a tool for early indication of toxicity in Lemna-tests
Vesna Peršić1, Tamara Đerđ1, Martina Varga1
1The University of Osijek, Department of Biology, Cara Hadrijana 8A, 31 000 Osijek, Croatia.
Abstract:
This paper presents an application of continuous monitoring of the emission and uptake rate of CO2 in Lemna toxicity test. On a real-time basis, the CO2 concentration data were collected by the Arduino platform-based respiratory activity measuring system (ResTox) and reported as CO2 concentration dynamic curves. The results of CO2 measurements demonstrated that tested metals (Co, Cu, Hg, and Cd), as well as herbicides (nicosulfuron, diquat, and tembotrione), stimulated the CO2 exchange rates at low doses, while at high doses CO2 exchange rates were inhibited. The addition of higher concentrations of clopyralid stimulated photosynthetic activity and caused a higher increase in respiration rates indicating its mode of action as auxin mimic herbicide. The results obtained underline the necessity of considering other biological endpoints like continuous measurements of gas exchange from the very beginning of exposure to toxicants. Simultaneous measurements of real-time CO2 concentrations, as the primary effect of toxicant mode of action, and processes that are supported by carbon flux, as the secondary effect or endpoint, are needed to relate actual and substrate-induced or inhibited respiration and photosynthesis to those processes. Therefore, continuous measurements of CO2 exchange rates can be implemented for the initial screening of potential toxicity to give valuable information that is needed for further examination of toxicity mechanisms and risk assessment.
More Related Videos
08:59Measuring Sub-23 Nanometer Real Driving Particle Number Emissions Using the Portable DownToTen Sampling System
Published on: May 22, 2020
09:34Implementation of Portable Emissions Measurement Systems PEMS for the Real-driving Emissions RDE Regulation in Europe
Published on: December 4, 2016
Related Concept Videos
Indicators
Emission Spectra
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Mechanical Ventilation I: Indication and Settings
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...