Usefulness of Oximetry Paradoxus to Diagnose Cardiac Tamponade
Rami Doukky1, Gabriel Improvola2, Michael J Shih2
1Division of Cardiology, Cook County Health, Chicago, Illinois; Division of Cardiology, Rush University Medical Center, Chicago, Illinois.
Abstract:
Although echocardiography is usually diagnostic of cardiac tamponade, it may not be readily available at the point-of-care. We sought to develop and validate a measurement of respirophasic variation in the amplitude of pulse oximetry plethysmographic waveforms as a diagnostic tool for cardiac tamponade. Pulse oximetry plethysmographic waveforms were recorded, and the ratio of maximum-to-minimum measured amplitude of these waveforms from one respiratory cycle was calculated by blinded observers. Ratios from 3 consecutive respiratory cycles were then averaged to derive an "oximetry paradoxus" ratio. Cardiac tamponade was independently confirmed or excluded according to a "blinded" objective interpretation of echocardiography or right heart catheterization. Seventy four subjects were enrolled (51% men; mean age 54 ± 15 years); 19 of whom had cardiac tamponade. Oximetry paradoxus area under the curve for diagnosis of cardiac tamponade was 0.90 (95% confidence interval, 0.84 to 0.97); its diagnostic performance was superior to sphygmomanometer-measured pulsus paradoxus (area under the curve difference = 0.16, p = 0.022). In a derivation cohort (n = 37; tamponade, 9 cases), 3 diagnostic oximetry paradoxus thresholds were identified and validated in an independent validation cohort (n = 37; tamponade, 10 cases): 1.2 (100% sensitivity, 44% specificity), 1.5 (80% sensitivity, 81% specificity), and 1.7 (80% sensitivity, 89% specificity). Furthermore, oximetry paradoxus was significantly reduced after draining pericardial fluid. In conclusion, we defined and validated oximetry paradoxus as a simple and ubiquitous point-of-care test to diagnose cardiac tamponade using respirophasic changes in pulse plethysmography waveforms. This test can aid in identifying patients with cardiac tamponade, thus expediting confirmatory testing and life-saving treatment.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...