Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Nuclear Fusion02:45

Nuclear Fusion

33.9K
The process of converting very light nuclei into heavier nuclei is also accompanied by the conversion of mass into large amounts of energy, a process called fusion. The principal source of energy in the sun is a net fusion reaction in which four hydrogen nuclei fuse and ultimately produce one helium nucleus and two positrons.
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
33.9K
Reliability and Validity01:29

Reliability and Validity

13.9K
Reliability and validity are two important considerations that must be made with any type of data collection. Reliability refers to the ability to consistently produce a given result. In the context of psychological research, this would mean that any instruments or tools used to collect data do so in consistent, reproducible ways.
13.9K
Internal Energy02:00

Internal Energy

36.8K
The total of all possible kinds of energy present in a substance is called the internal energy (U), sometimes symbolized as E. Suppose a system with initial internal energy, Uinitial, undergoes a change in energy (transfer of work or heat), and the final internal energy of the system is Ufinal. Change in internal energy equals the difference between Ufinal and Uinitial.
36.8K
Internal Energy01:29

Internal Energy

7.0K
The internal energy of a thermodynamic system is the sum of the kinetic and potential energies of all the molecules or entities in the system. The kinetic energy of an individual molecule includes contributions due to its rotation and vibration, as well as its translational energy. The potential energy is associated only with the interactions between one molecule and the other molecules of the system. Neither the system's location nor its motion is of any consequence as far as the internal...
7.0K
Internal Receptors01:31

Internal Receptors

74.7K
Many cellular signals are hydrophilic and therefore cannot pass through the plasma membrane. However, small or hydrophobic signaling molecules can cross the hydrophobic core of the plasma membrane and bind to internal, or intracellular, receptors that reside within the cell. Many mammalian steroid hormones use this mechanism of cell signaling, as does nitric oxide (NO) gas.
74.7K
Data Validation01:15

Data Validation

1.9K
Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
1.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Advancing justice: The impact of Brazil's convict genetic profile identification project after 5 years.

Science & justice : journal of the Forensic Science Society·2024
Same author

Microsatellites' mutation modeling through the analysis of the Y-chromosomal transmission: Results of a GHEP-ISFG collaborative study.

Forensic science international. Genetics·2024
Same author

FANCJ DNA helicase is recruited to the replisome by AND-1 to ensure genome stability.

EMBO reports·2024
Same author

Sudden death in young South European population: a cross-sectional study of postmortem cases.

Scientific reports·2023
Same author

LC-MS-MS-MS3 for the determination and quantification of ∆9-tetrahydrocannabinol and metabolites in blood samples.

Journal of analytical toxicology·2023
Same author

Second GHEP-ISFG exercise for DVI: "DNA-led" victims' identification in a simulated air crash.

Forensic science international. Genetics·2021
Same journal

Preliminary determination of <i>a priori</i> information for forensic lubricant analysis in sexual assault cases.

Forensic sciences research·2026
Same journal

Interpretation of drug trafficking patterns and utility of forensic intelligence.

Forensic sciences research·2026
Same journal

The first identified skeletal collection of the Azores archipelago, Portugal.

Forensic sciences research·2026
Same journal

Comparative analysis of DNA collection techniques applied to disposable 3-layer earloop face masks.

Forensic sciences research·2026
Same journal

To test or not to test for body fluids: integration of body fluid identification and direct PCR in one workflow.

Forensic sciences research·2026
Same journal

Is he really my relative? Kinship cases in substructured populations: a study on the Lebanese population.

Forensic sciences research·2026
See all related articles

Related Experiment Video

Updated: Feb 2, 2026

Method of Studying Palatal Fusion using Static Organ Culture
04:58

Method of Studying Palatal Fusion using Static Organ Culture

Published on: September 19, 2015

9.4K

PowerPlex® fusion 6C system: internal validation study.

Ana Boavida1, Vanessa Bogas1, Lisa Sampaio1

  • 1Forensic Genetic Service, Centre Branch, National Institute of Legal Medicine and Forensic Sciences,Coimbra, Portugal.

Forensic Sciences Research
|November 29, 2018
PubMed
Summary
This summary is machine-generated.

The PowerPlex® Fusion 6C System, a polymerase chain reaction (PCR) kit, was validated for forensic genetic analysis. This robust kit demonstrated reliable performance for amplifying 27 loci, meeting forensic laboratory standards.

Keywords:
Forensic sciencePowerPlex® Fusion 6Camplificationforensic geneticsshort tandem repeat sequence (STRs)validation

More Related Videos

Fabricating Optical-quality Glass Surfaces to Study Macrophage Fusion
08:50

Fabricating Optical-quality Glass Surfaces to Study Macrophage Fusion

Published on: March 14, 2018

7.6K
How to Calculate and Validate Inter-brain Synchronization in a fNIRS Hyperscanning Study
05:33

How to Calculate and Validate Inter-brain Synchronization in a fNIRS Hyperscanning Study

Published on: September 8, 2021

7.5K

Related Experiment Videos

Last Updated: Feb 2, 2026

Method of Studying Palatal Fusion using Static Organ Culture
04:58

Method of Studying Palatal Fusion using Static Organ Culture

Published on: September 19, 2015

9.4K
Fabricating Optical-quality Glass Surfaces to Study Macrophage Fusion
08:50

Fabricating Optical-quality Glass Surfaces to Study Macrophage Fusion

Published on: March 14, 2018

7.6K
How to Calculate and Validate Inter-brain Synchronization in a fNIRS Hyperscanning Study
05:33

How to Calculate and Validate Inter-brain Synchronization in a fNIRS Hyperscanning Study

Published on: September 8, 2021

7.5K

Area of Science:

  • Forensic Science
  • Molecular Biology
  • Genetics

Background:

  • Forensic genetic analysis relies on validated DNA amplification kits.
  • Implementing new kits requires rigorous evaluation for accuracy and reliability.
  • The PowerPlex® Fusion 6C System offers multiplex amplification of 27 loci.

Purpose of the Study:

  • To describe the validation process for the PowerPlex® Fusion 6C System.
  • To assess the kit's suitability for routine forensic genetic laboratory implementation.
  • To ensure the kit meets established forensic DNA analysis guidelines.

Main Methods:

  • Validation followed the Scientific Working Group on DNA Analysis Methods guidelines.
  • Evaluated parameters included specificity, analytical thresholds, sensitivity, and precision.
  • Assessed mixture studies, DNA control samples, proficiency testing, and PCR procedure modifications.

Main Results:

  • The PowerPlex® Fusion 6C System demonstrated robustness in validation studies.
  • Results were consistent with the manufacturer's developmental validation.
  • Performance in certain parameters exceeded expectations.

Conclusions:

  • The PowerPlex® Fusion 6C System is a reliable tool for forensic genetic analysis.
  • The kit is suitable for implementation in routine forensic laboratory workflows.
  • Validation confirmed the kit's high performance and robustness.