Related Experiment Video
Updated: Feb 2, 2026

Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Evaluation of cone-beam computed tomography diagnostic image quality using cluster signal-to-noise analysis
Warangkana Weerawanich1,2, Mayumi Shimizu3, Yohei Takeshita4
1Department of Oral and Maxillofacial Radiology, Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. yui@rad.dent.kyushu-u.ac.jp.
Objectives:
(1) We sought to assess correlation among four representative parameters from a cluster signal-to-noise curve (true-positive rate [TPR] corresponding to background noise, accuracy corresponding to background noise, maximum TPR, and maximum accuracy) and the diagnostic accuracy of the identification of the mandibular canal using data from observers in a previous study, under the same exposure conditions. (2) We sought to clarify the relationship between the hole depths of a phantom and diagnostic accuracy.
Methods:
CBCT images of a Teflon plate phantom with holes of decreasing depths from 0.7 to 0.1 mm were analyzed using the FindFoci plugin of ImageJ. Subsequently, we constructed cluster signal-to-noise curves by plotting TPRs against false-positive rates. The four parameters were assessed by comparing with the diagnostic accuracy calculated from the observers. To analyze image contrast ranges related to detection of mandibular canals, we determined five ranges of hole depths, to represent different contrast ranges-0.1-0.7, 0.1-0.5, 0.2-0.6, 0.2-0.7 and 0.3-0.7 mm-and compared them with observers' diagnostic accuracy.
Results:
Among the four representative parameters, accuracy corresponding to background noise had the highest correlation with the observers' diagnostic accuracy. Hole depths of 0.3-0.7 and 0.1-0.7 mm had the highest correlation with observers' diagnostic accuracy in mandibles with distinct and indistinct mandibular canals, respectively.
Conclusions:
The accuracy corresponding to background noise obtained from the cluster signal-to-noise curve can be used to evaluate the effects of exposure conditions on diagnostic accuracy.
More Related Videos
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Heart Failure IV: Classification and Diagnostic Evaluation
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Irritable Bowel Syndrome II: Clinical Features and Diagnostic Evaluation
Irritable Bowel Syndrome (IBS) is classified into subtypes based on the predominant bowel habits as determined by the Bristol Stool Form Scale (BSFS). The subtypes are:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation