Related Experiment Video
Updated: Feb 2, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Arterial Oxygen Saturation, Pulse Oximetry, and Cerebral and Tissue Oximetry in Hypobaric Hypoxia
Abstract:
INTRODUCTION: Clinical accuracy of pulse oximeters (giving Spo₂) is routinely tested down to an Sao₂ of 70%, but lower oxygen saturations are often experienced during hypobaric hypoxia. Cerebral (Sco₂) and peripheral tissue (Sto₂) oxygen saturations can be measured using near infra-red spectroscopy. In a project simulating oxygen system failure during high altitude-high opening parachuting (HAHO), Sao₂, Spo₂, Sco₂, and forearm Sto₂ were measured. The aim of the present analysis was to explore the agreement between Sao₂ and the three noninvasive measurements of hypoxemia (Spo₂, Sco₂, and Sto₂).METHODS: Healthy volunteers from the Norwegian Special Operations Commando were studied in a hypobaric chamber as supplemental oxygen was removed at 301 hPa ambient pressure (30,000 ft) and recompressed at 25 hPa · min-1 (1000 ft · min-1) to ground level simulating a HAHO parachute flight. Sao₂ was compared with Spo₂, Sco₂, and Sto₂ in scatterplots and Bland-Altman plots, calculating bias and limits of agreement (LOA).RESULTS: The bias ± LOA were: Sao₂ vs. Spo₂: -5.8% ± 16, Sao₂ vs. Sco₂: -3.4% ± 11, and Sao₂ vs. Sto₂: 17% ± 30. The bias for Sao₂ vs. Spo₂ was dependent on the range of values, and correcting for this with a sloped bias line reduced the LOA to ± 8.2%.DISCUSSION: There were wide limits of agreement between Sao₂ and Spo₂. Sao₂ and Sco₂ agreed better, whereas Sao₂ and forearm Sto₂ had wide LOA. The agreement between Sao₂ and Spo₂ improved when correcting for the underestimation of Spo₂ at low values. There is a poor agreement between Spo₂ and the gold standard Sao₂ during extreme hypobaric hypoxemia.Ottestad W, Kåsin JI, Høiseth LØ. .
More Related Videos
07:51Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
12:03Detection of Microregional Hypoxia in Mouse Cerebral Cortex by Two-photon Imaging of Endogenous NADH Fluorescence
Published on: February 21, 2012
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Solution Equilibrium and Saturation
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...