Defining the optimal criterion for separating gases using polymeric membranes
Related Experiment Video
Updated: Feb 1, 2026

Optimized Analysis of DNA Methylation and Gene Expression from Small, Anatomically-defined Areas of the Brain
Published on: July 12, 2012
1Department of Chemical Engineering, Columbia University, New York, New York 10027, USA. sk2794@columbia.edu.
Abstract:
Polymeric membranes are efficient in separating gas mixtures, typically by exploiting the sieving mechanism. What controls the sieve size of a given polymer matrix is unclear, although one line of thought implies that the local cage size, defined by the dynamic motions of the glassy polymer matrix, is the relevant metric. Here, we use coarse-grained molecular dynamics simulations and show that the sieve size is defined by a static cavity size controlled by polymer chain stiffness (a packing-driven metric) combined with the local cage-like motions of the polymer host. The best separation performance for a pair of gases is when this combined metric is roughly half way between the diameters of the gases in question, with the static and dynamic quantities contributing roughly equally. For the various models simulated we find the existence of an upper bound correlation which passes through this optimal point and has a slope expected from the Freeman model, namely , where the d's correspond to the kinetic diameters of the gases in question. Our results thus demonstrate that the relevant free volume size that affects gas transport in these condensed phases is defined by both static and dynamic measures.
Related Concept Videos
Noble Gases
The elements in group 18 are noble gases (helium, neon, argon, krypton, xenon, and radon). They earned the name “noble” because they were assumed to be nonreactive since they have filled valence shells. In 1962, Dr. Neil Bartlett at the University of British Columbia proved this assumption to be false.
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Molecular Comparison of Gases, Liquids, and Solids
Routh-Hurwitz Criterion I
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
Routh-Hurwitz Criterion II
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.

