When results matter: reliable creatinine concentrations in hyperbilirubinemia patients
Roseri J A C Roelofsen-de Beer1, Bertrand D van Zelst1, Aram B Vroling1
1Department of Clinical Chemistry, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
Abstract:
Background Failure to report a creatinine concentration, especially in icteric patients who are eligible for a liver transplant, can result in a life-threatening situation. We assessed the influence of bilirubin interference on several creatinine assays and investigated ways to circumvent icteric interference without interfering with our normal automated sample logistics. Methods Using icteric patient sera (total bilirubin >255 μmol/L) we determined creatinine concentrations using an enzymatic and Jaffé assay (Roche Diagnostics) in both normal (i.e. undiluted) and decreased mode (i.e. diluted) as well as an enzyme-coupled amperometric assay on a Radiometer ABL837 FLEX analyzer. Creatinine concentrations from the five methods were compared with an in-house developed LC-MS/MS method. Passing and Bablok (proportional and constant bias) as well as difference plot parameters (bias and 95% limits of agreement [LoA]) were calculated. Interferograph-based regression analysis of the enzymatic and Jaffé results was used to investigate if such an approach could be used to report corrected creatinine concentrations in icteric patient sera. Results In icteric patient sera the enzyme-coupled amperometric assay was hardly influenced by icteric interference as shown by a difference plot bias of -1.5% (95% LoA -11.6 to +8.5%). The undiluted Jaffé method had a bias of -1.4% with a very broad 95% LoA (-35.1 to +32.2%) emphasizing the poor specificity of this method. The undiluted enzymatic method had the largest bias (-13.4%, 95% LoA -35.8 to +9.0%). Diluting sera in the enzymatic method did not improve the bias (-10.5%, 95% LoA -25.4 to 4.4%), while diluting the Jaffé method resulted in a bias increase (+11.4%, 95% LoA -14.7 to 37.5%). Using interferograph-based regression analysis we were able to reliably correct enzymatic creatinine concentrations in 97 out of 100 icteric patient sera. Conclusions Analytically, quantifying creatinine in icteric sera using the Radiometer ABL837 FLEX analyzer is the method of choice within our laboratory. However, not all laboratories are equipped with this method and even if available, the limited number of highly icteric patient sera makes this method costly. For those laboratories using the Roche enzymatic method, mathematically correcting an icteric creatinine concentration using an interferograph based on an LC-MS/MS reference method is a suitable alternative to report reliable creatinine results in icteric patients.
More Related Videos
07:43Using 22C3 Anti-PD-L1 Antibody Concentrate on Biopsy and Cytology Samples from Non-small Cell Lung Cancer Patients
Published on: September 25, 2018
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Classifying Matter by State
Reliability and Validity
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
Physical and Chemical Properties of Matter