Comparison of practical methods in clinical sites for estimating cerebral blood flow during balloon test occlusion
Shoichi Tani1, Hirotoshi Imamura1, Katsunori Asai2
11Department of Neurosurgery, Kobe City Medical Center General Hospital, Kobe.
Objective:
The authors sought to compare methods of measurement for venous phase delay (VPD) or mean stump pressure (MSTP) to rank their potential to predict ischemic tolerance during balloon test occlusion in the internal carotid artery, exploring a more correlative and convenient way to measure cerebral blood flow (CBF) that could be utilized even in the acute phase or in institutions not adequately equipped to measure CBF during the test.
Methods:
X-ray angiography perfusion analysis using diagnostic digital subtraction angiography (DSA) equipment enables 1-step examination (without any room-to-room transfer of patients) to measure CBF, VPD, and MSTP completely simultaneously, which has not been accomplished by any previous perfusion studies.
Results:
This analysis was applied to 17 patients and resulted in successful estimation of all 3 parameters in each case. The average VPD of several cortical veins had a strong correlation with relative CBF (rCBF) between bilateral hemispheres with a correlation coefficient of 0.89443, a correlation as strong as that (0.90357) of the "approximate VPD," which is interpreted based on the trend line of the scatterplot of the time to peak contrast opacification in cortical veins and their spatial positioning from the median sagittal plane. MSTP and classic visual determination of VPD have weaker correlation coefficients with rCBF (0.56119 and 0.70048, respectively). Overall, subjective visual determination in combination with the calculation of the trend line to estimate VPD provided a considerably strong correlation with rCBF (R = 0.86660) without any dedicated software or hardware.
Conclusions:
VPD has a stronger correlation with rCBF than MSTP. rCBF could be successfully predicted on common DSA equipment, even by visual determination without expensive software, if the trend line is adopted for processing to estimate VPD.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Blood Flow
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Conserved Binding Sites
Binding sites are often located in large pockets, and if their location on a protein’s surface is unknown, it can be predicted using various approaches. The energetic method computationally...
Applications of Integration to Find Blood Flow
Ligand Binding Sites
Protein-ligand interactions are quite specific; even though numerous potential ligands surround a cellular protein at any given time, only a particular ligand can bind to that protein. Moreover, a ligand binds only to a dedicated area on the surface of the protein, known as the...