Related Experiment Video
Updated: Feb 1, 2026

An R-Based Landscape Validation of a Competing Risk Model
Published on: September 16, 2022
Development and validation of a predictive risk factor model for epidural re-siting in women undergoing labour
John Song En Lee1, Rehena Sultana2, Nian Lin Reena Han3
1Department of Women's Anaesthesia, KK Women's and Children's Hospital, 100 Bukit Timah Road, Singapore, 229899, Singapore.
Background:
Epidural catheter re-siting in parturients receiving labour epidural analgesia is distressing to the parturient and places them at increased complications from a repeat procedure. The aim of this study was to develop and validate a clinical risk factor model to predict the incidence of epidural catheter re-siting in labour analgesia.
Methods:
The data from parturients that received labour epidural analgesia in our centre during 2014-2015 was used to develop a predictive model for epidural catheter re-siting during labour analgesia. Multivariate logistic regression analysis was used to identify factors that were predictive of epidural catheter re-siting. The forward, backward and stepwise variable selection methods were applied to build a predictive model, which was internally validated. The final multivariate model was externally validated with the data collected from 10,170 parturients during 2012-2013 in our centre.
Results:
Ninety-three (0.88%) parturients in 2014-2015 required re-siting of their epidural catheter. The training data set included 7439 paturients in 2014-2015. A higher incidence of breakthrough pain (OR = 4.42), increasing age (OR = 1.07), an increased pain score post-epidural catheter insertion (OR = 1.35) and problems such as inability to obtain cerebrospinal fluid in combined spinal epidural technique (OR = 2.06) and venous puncture (OR = 1.70) were found to be significantly predictive of epidural catheter re-siting, while spontaneous onset of labour (OR = 0.31) was found to be protective. The predictive model was validated internally on a further 3189 paturients from the data of 2014-2015 and externally on 10,170 paturients from the data of 2012-2013. Predictive accuracy of the model based on C-statistic were 0.89 (0.86, 0.93) and 0.92 (0.88, 0.97) for training and internal validation data respectively. Similarly, predictive accuracy in terms of C-statistic was 0.89 (0.86, 0.92) based on 2012-2013 data.
Conclusion:
Our predictive model of epidural re-siting in parturients receiving labour epidural analgesia could provide timely identification of high-risk paturients required epidural re-siting.
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Conserved Binding Sites
Binding sites are often located in large pockets, and if their location on a protein’s surface is unknown, it can be predicted using various approaches. The energetic method computationally...
Reliability and Validity
Transcription Factors
In Vitro Drug Release Testing: Overview, Development and Validation

