Related Experiment Video
Updated: Feb 1, 2026

Standardized Method for Measuring Collection Efficiency from Wipe-sampling of Trace Explosives
Published on: April 10, 2017
Trace detection of some nitro-explosives using thermal mediated immunochemical defragmented method
Shilpa Chaudhary1, Praveen Sonkusre2, K K Bhasin3
1CSIR-Institute of Microbial Technology, Sector 39-A, Chandigarh 160036, India; Department of Chemistry, Panjab University, Chandigarh 160014, India.
Abstract:
A new immunoassay format using thermally induced defragmentation of some nitro-explosives with a high degree of selectivity is reported. Specific antibodies against three widely used explosives, 2,4,6-trinitrotoluene (TNT), 1,3,5-trinitroperhydro-1,3,5-triazine (RDX), and pentaerythritol tetranitrate (PETN) were generated by designing suitable haptens using geometry optimization modules. These in-house generated antibodies were used in a newly developed thermal mediated immunochemical biosensing technique which involves the binding of specific antibodies to respective nitro-explosives on a microtiter strip, resulting in the formation of specific immunocomplex. Heating the specific immuno-complex formed on microtiter wells resulted in thermal lysis of nitro-explosives to generate nitrite ions. These ions react with Griess reagent to form a colored chromophore which correlates the concentration of individual explosive in the sample. The present work fulfills the need for an improved explosive detecting system that is highly specific and capable of quickly determining the presence of nitrate containing explosives from a mixture pool.
Related Concept Videos
Preparation of Amines: Reduction of Oximes and Nitro Compounds
Though catalytic hydrogenation can reduce nitrobenzenes, the reduction is nonselective in the presence of other functional groups. For instance, if nitrobenzene contains an aldehyde group,...
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Thermal Strain
Thermal Expansion
Thermal Stress

