Large scale parallelization in stochastic coupled cluster
J S Spencer1, V A Neufeld2, W A Vigor3
1Department of Materials, Imperial College London, Exhibition Road, London SW7 2AZ, United Kingdom.
The Journal of Chemical Physics
|December 4, 2018
Summary
Stochastic coupled cluster Monte Carlo methods offer a scalable and efficient alternative to traditional quantum chemistry calculations. This new algorithm improves computational efficiency for large electronic structure problems.
Area of Science:
- Quantum Chemistry
- Computational Physics
- Electronic Structure Theory
Background:
- Coupled cluster theory is fundamental to electronic structure calculations.
- Deterministic algorithms face scalability challenges with increasing system size.
- Stochastic quantum chemistry methods offer advantages in computational demand and scalability.
Purpose of the Study:
- To present a highly parallelizable algorithm for coupled cluster Monte Carlo.
- To investigate the algorithm's performance on model systems.
- To introduce improvements to the sampling methodology.
Main Methods:
- Developed a parallelized coupled cluster Monte Carlo algorithm.
- Employed sampling of excitor clusters over multiple time steps.
- Tested the algorithm on uniform electron gas and water dimer systems.
- Included coupled cluster levels up to quadruple excitations.
Main Results:
- Demonstrated a highly parallelizable and scalable algorithm.
- Investigated performance at various coupled cluster truncation levels.
- Introduced and described 'full non-composite' and 'multi-spawn' sampling improvements.
Conclusions:
- Stochastic coupled cluster methods provide an efficient and scalable approach.
- The presented algorithm enables accurate calculations for larger systems.
- Improvements enhance the practical applicability of coupled cluster Monte Carlo.
More Related Videos
Related Concept Videos
pH Scale
79.7K
Hydronium and hydroxide ions are present both in pure water and in all aqueous solutions, and their concentrations are inversely proportional as determined by the ion product of water (Kw). The concentrations of these ions in a solution are often critical determinants of the solution’s properties and the chemical behaviors of its other solutes. Two different solutions can differ in their hydronium or hydroxide ion concentrations by a million, billion, or even trillion times. A common means of...
79.7K
Parallel Resonance
559
The parallel RLC circuit is an arrangement where the resistor (R), inductor (L), and capacitor (C) are all connected to the same nodes and, as a result, share the same voltage across them. The parallel RLC circuit is analyzed in terms of admittance (Y), which reflects the ease with which current can flow. The admittance is given by:
559
Parallel Processing
719
The brain processes sensory information rapidly due to parallel processing, which involves sending data across multiple neural pathways at the same time. This method allows the brain to manage various sensory qualities, such as shapes, colors, movements, and locations, all concurrently. For instance, when observing a forest landscape, the brain simultaneously processes the movement of leaves, the shapes of trees, the depth between them, and the various shades of green. This enables a quick and...
719
Resistors In Parallel
6.2K
Resistors are in parallel when one end of all the resistors are connected to a continuous wire of negligible resistance and the other end of all the resistors are also connected to one another through a continuous wire of negligible resistance. In the case of a parallel configuration, the potential drop across each resistor is the same. Current through each resistor can be found using Ohm’s law, I = V/R, where the voltage is constant across each resistor. The sum of the individual currents...
6.2K
Series and Parallel Capacitors
9.4K
Capacitors, fundamental components in electronic circuits, can be connected in series and/or parallel configurations. Each configuration has different impacts on the overall behavior of the circuit.
First, consider capacitors connected in series to a battery. In this configuration, the plate connected to the battery's positive terminal develops a positive charge, while the plate attached to the negative terminal becomes negatively charged. An equal magnitude of charge is induced on the...
First, consider capacitors connected in series to a battery. In this configuration, the plate connected to the battery's positive terminal develops a positive charge, while the plate attached to the negative terminal becomes negatively charged. An equal magnitude of charge is induced on the...
9.4K
Cluster Sampling Method
14.7K
Appropriate sampling methods ensure that samples are drawn without bias and accurately represent the population. Because measuring the entire population in a study is not practical, researchers use samples to represent the population of interest.
To choose a cluster sample, divide the population into clusters (groups) and then randomly select some of the clusters. All the members from these clusters are in the cluster sample. For example, if you randomly sample four departments from your...
To choose a cluster sample, divide the population into clusters (groups) and then randomly select some of the clusters. All the members from these clusters are in the cluster sample. For example, if you randomly sample four departments from your...
14.7K


