Related Experiment Video
Updated: Feb 1, 2026

Author Spotlight: Self-Assessment Protocol for Predicting Psoriatic Arthritis in Psoriasis Patients
Published on: March 1, 2024
Non-Radiographic Severity Measurement of Pectus Excavatum
David P Bliss1, Nathan A Vaughan2, Ryan M Walk3
1Division of Pediatric Surgery/Department of Surgery, University of Colorado School of Medicine, Children's Hospital Colorado, Colorado Springs, Colorado.
Background:
To avoid the radiation exposure of CT imaging and the expense of CT or MRI studies, we sought to develop a non-radiographic severity measurement of pectus excavatum based on 3D photogrammetric imaging.
Methods:
Over 28 mo, ten consecutive patient volunteers with pectus excavatum underwent 3D stereophotogrammetric imaging. The surface width to surface depth ratio (Surface Lengths Pectus Index), the chest deformity's surface area to total chest surface area (Pectus Surface Area Ratio), and the chest deformity's volume to total chest volume (Pectus Volume Ratio) were calculated. Simple linear regression analysis compared the Surface Lengths Pectus Index, Pectus Surface Area Ratio, and Pectus Volume Ratio calculations each to the corresponding known CT pectus index.
Results:
The correlation between CT pectus index versus Surface Lengths Pectus Index yielded an R-squared value of 0.7637 and a P value of 0.0013. A CT pectus index of 3.4 or greater (eight patients) corresponded to a Surface Lengths Pectus Index of 1.86 or greater (six patients). The CT pectus index versus Pectus Surface Area Ratio (R-squared = 0.4627, P = 0.0305) and the CT pectus index versus the Pectus Volume Ratio (R-squared = 0.3048, P = 0.0990) demonstrated less correlation.
Conclusion:
Surface Lengths Pectus Index corresponds to the CT pectus index and may be adequate to determine severity of pectus excavatum in some patients.
More Related Videos
07:22Glycemic Impact on Knee Osteoarthritis Symptoms on Physical, Radiographic, and Inflammatory Markers among Individuals Aged 50 and Over with Diabetes
Published on: March 7, 2025
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Related Concept Videos
Measures of Central Tendency
Measurement: Standard Units
Measuring Reaction Rates
Uncertainty in Measurement: Significant Figures
Measurement: Derived Units
Units of Measurement
There are various well-known historical measurement systems, such as the Babylonian system, the Roman system, the Egyptian system, the Olympian system, the British system, and the Indus...