Related Experiment Video
Updated: Feb 1, 2026

Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
Published on: February 10, 2015
A new method of estimating scapular orientation during various shoulder movements: A comparison of three non-invasive
Aoi Matsumura1, Atsushi Ueda2, Yasuo Nakamura2
1Graduate School of Health and Sports Science, Doshisha University, Kyoto, Japan; TAKE PHYSICAL CONDITIONING Inc., Kyoto, Japan.
Abstract:
The conventional acromion marker cluster (AMC) method used to estimate scapular orientation cannot adequately represent complex shoulder movements due to soft tissue artifacts. The regression method may have nonlinear error changes depending on humeral elevation angle and elevation plane. Therefore, we aimed to develop a new method of estimating scapular orientation using curved surface interpolation during various shoulder movements, and to compare its accuracy with conventional and regression methods. Thirteen healthy men were recruited. AMC and refractive markers for bony landmarks were placed on the skin. During the preprocess, several shoulder postures, including different arm elevations and elevation planes, were measured using the motion capture system. Premeasured data were used to calibrate the positional relationship between AMC and scapula using curved surface interpolation. Subsequently, scapular orientations were estimated by measuring AMC and body markers of any shoulder posture. To evaluate the accuracy of our methods, 25 elevation postures and six tasks involving postures common to activities of daily living were applied. For tasks requiring greater arm elevation angles, the root mean square error was less in our method than in the conventional and regression methods. Therefore, our method could improve the accuracy of estimating scapular orientation in various elevation postures.
Related Concept Videos
Methods of Documentation I: Source-Oriented Records
In an SOR, each discipline involved in patient care maintains a separate medical record section. This record-keeping method enables easy tracking of patient progress and ensures healthcare staff have access to up-to-date information.
Key Attributes include the following:
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Muscles of the Shoulder
Anterior Thoracic Muscles
The anterior thoracic muscles include the serratus anterior, subclavius, and...
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
The Scientific Method