Related Experiment Video
Updated: Feb 1, 2026

Fabrication of Thin Film Silver/Silver Chloride Electrodes with Finely Controlled Single Layer Silver Chloride
Published on: July 1, 2020
Interaction of prednisone with dsDNA at silver nanoparticles/poly(glyoxal-bis(2-hydroxyanil))/dsDNA modified
Gözde Aydoğdu Tığ1, Derya Koyuncu Zeybek2, Bülent Zeybek3
1Department of Chemistry, Ankara University, Ankara, Turkey.
Abstract:
This paper reports the fabrication of an electrochemical DNA biosensor for the electrochemical determination of prednisone (PRD), which is a synthetic corticosteroid. For this purpose, silver nanoparticles (AgNPs) and a new polymer film poly(glyoxal-bis(2-hydroxyanil)) (P(GBHA)) were electrochemically deposited on a glassy carbon electrode (GCE), respectively. Then, an electrochemical DNA biosensor was prepared onto this electrode surface (GCE/AgNPs/P(GBHA)) by the immobilization of dsDNA using a chronoamperometry method. The proposed electrode was characterized by FESEM, XPS, and cyclic voltammetry (CV). The interaction between the PRD and dsDNA immobilized on the GCE/AgNPs/P(GBHA) electrode was investigated via a differential pulse voltammetry (DPV) method and UV-Vis spectrophotometry. The experimental factors affecting the interaction between the PRD concentration and dsDNA were optimized. The fabricated biosensor showed a wide linear response in a PRD concentration range of 1.0-50.0 μg mL-1 depending on both the adenine and guanine base signals. The detection limit based on the guanine and adenine signals was 0.3 μg mL-1 and 0.25 μg mL-1, respectively. The sensor exhibited excellent anti-interferential ability, good stability and reproducibility and was satisfactorily employed for the electrochemical assay of PRD in serum samples. The new DNA biosensor can be utilized for the sensitive, accurate and rapid analysis of PRD.
Related Concept Videos
Standard Electrode Potentials
Development of Analytical Methods
Analyte Adsorption and Distribution
Jung's Analytical Theory
Graphical and Analytic Representation of Sinusoids
The first step is measuring the peak-to-peak value, which is twice the amplitude of the sinusoid. This provides information about the maximum voltage swing of the waveform.
Secondly, the period and angular frequency are determined. The period is the time taken for one complete cycle of the waveform, while...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...

