Related Experiment Video
Updated: Feb 1, 2026

Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
Correlation of optic disc morphometry and optic disc microvasculature assessed with optical coherence tomography
Khalil Ghasemi Falavarjani1, Hamideh Shenazandi1, Dariush Naseri1
1Eye Research Center and Department of Ophthalmology, Rassoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran.
Objective:
To compare optic disc microvasculature measurements to the disc morphometrics in normal eyes.
Design:
Cross-sectional study.
Participants:
Fifty-eight healthy subjects.
Methods:
Enface 4.5x4.5 mm optical coherence tomography angiography images were obtained from the optic disc of healthy individuals. The radial peripapillary capillary (RPC) and the nerve head (NH) en face images were obtained. Also, spectral domain OCT measurements of the peripapillary nerve fibre layer (NFL) thickness were recorded. Correlations of the vessel density and NFL measurements with optic disc morphometrics were analyzed.
Results:
Fifty-eight eyes of 58 patients were included. Mean peripapillary NFL thickness was 99.77 ± 8.47 µm. The mean disc area was 2.15 ± 0.34 mm2 (range, 1.48-3.02 mm2) with an average cup/disc area ratio of 0.27 ± 0.14 (range, 0.0-0.6). On the RPC en face image, the mean vessel density of the whole image, peripapillary, and inside disc was 55.52 ± 2.90, 62.42 ± 3.30, and 45.77 ± 9.24%, respectively. On the NH en face images, the mean vessel density of the whole image, peripapillary, and inside disc was 55.69 ± 3.04, 60.15 ± 2.79, and 52.69 ± 5.31%, respectively. The NH vessel density in the inside disc area correlated with the cup/disc area ratio (R = -0.44, p < 0.001). The association of RPC vessel density in the inside disc area with the cup/disc area ratio was significant (R= -0.88, p < 0.001). The RPC vessel density in the peripapillary area correlated with the cup/disc area ratio (R = 0.37, p = 0.004). Also, the RPC vessel density in the whole image was associated with the peripapillary NFL thickness (R = 0.32, p = 0.01).
Conclusion:
We observed a significant negative correlation between inside disc vessel density and cup/disc area ratio, but not to the disc area in normal eyes. In addition, the whole image RPC vessel density was revealed to be weakly correlated with the average RNFL thickness.
Related Concept Videos
Properties of Enantiomers and Optical Activity
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
Correlations
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Correlation
Two variables, for example, a and b, are said to be positively correlated if both variables move in the same direction. In other words, a positive correlation exists between two variables, a and b, if:

