Related Experiment Video For 18F-fluorodeoxyglucose positron emission tomography/computerized tomography
Updated: Feb 1, 2026

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
First case on fluorodeoxyglucose positron emission tomography/computerized tomography of a distant skip metastases to
Vincenzo Militano1, Sivakumar Muthu1, Naheed Farooq2
1Department of Nuclear Medicine, Central Manchester University Hospitals NHS Foundation Trust, Manchester, United Kingdom.
Abstract:
We are presenting the first case of a gastro-oesophageal junction adenocarcinoma with metastasis only to the intraparotid lymph node simulating Warthin's tumor. A 66-year-old man underwent an esophagogastroduodenoscopy that found circumferential ulcerated esophageal tumor beginning 40 cm from incisors resulting in stricture and two discrete erosions in the proximal third of esophagus. Biopsies from the stricture have demonstrated a poorly differentiated gastric adenocarcinoma. Computerized tomography (CT) confirmed the site of primary without evidence of distant metastasis. Positron emission tomography/CT showed high uptake in the known carcinoma in distal esophagus involving the gastro-oesophageal junction extending into the cardia of the stomach, the maximum standardized uptake value (SUVmax) 7.4. Furthermore, there was a focus of high-grade tracer activity, SUVmax 6.2, in the left intraparotid nodule which was initially thought to represent Warthin's tumor rather than metastasis; there was no evidence to suggest metastases elsewhere. Fine needle aspiration and biopsy from the enlarged intraparotid lymph node revealed that the histology was consistent with a poorly differentiated adenocarcinoma, metastasis from upper gastrointestinal tract.
More Related Videos
05:32Multimodal Bioluminescent and Positronic-emission Tomography/Computational Tomography Imaging of Multiple Myeloma Bone Marrow Xenografts in NOG Mice
Published on: January 7, 2019
10:20Automation of a Positron-emission Tomography PET Radiotracer Synthesis Protocol for Clinical Production
Published on: October 26, 2018
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Emission Spectra