United Reference Method for three-dimensional treatment evaluation
Shereef Shahen1, Manuel O Lagravère2, Gennaro Carrino1
1Department of Orthodontics, University of Campania Luigi Vanvitelli, Naples, Italy.
Background:
Reproducible and descriptive Three-dimensional treatment evaluation can enhance future treatment based on realistic results. So, the purpose of this study was to describe a new method for three-dimensional treatment evaluation showing how to use fully-automated craniofacial superimposition of CBCT records combined with reference system to obtain descriptive and comparable results. This new method was named United Reference Method (URM).
Methods:
URM is a combination of automated 3D superimposition on anterior cranial base surface anatomy and measurements based on reference system. It was developed to show how to use fully-automated superimposition to obtain descriptive numerical comparable values. The method is based on: one main reference system for both superimposed CBCT records, semi-automation to increase accuracy, all measurements are projections and auxiliary references to aid in landmarks identification and measurements. The method steps can be described following a four-step approach: (1) Superimposition performed through a fully automated, voxel-wise, rigid registration considering only cranial base as a stable structure; (2) Identification of reference landmarks once on the superimposed records for corrected Frankfort Horizontal plane (C-FH) construction and a new semi-automated constructed Sella point to correct Orbital asymmetry; (3) Head orientation of superimposed CBCT images based on the C-FH; (4) Identification of landmarks affected by treatment with the aid of auxiliary reference planes. Evaluation of linear or angular changes derived by projection of same pre- and post-treatment landmarks on the C-FH. Pre- and post-expansion CBCT scans of 20 unilateral cleft lip and palate patients were used to calculate intra and inter-rater reliability. (X, Y and Z) coordinates, mean, standard deviation (SD) and Intra-class Correlation Coefficient (ICC) were calculated.
Results:
The proposed coordinates for C-FH construction showed ICC ≥ 0.998 and SD ranging from 0.064 to 0.242 mm. On the other hand, excluded coordinates due to expected natural craniofacial asymmetry had the lowest reliability ICC ≥0.742 and SD dramatically increased up to 1.112 mm.
Conclusion:
URM showed adequate reliability so it can be used to produce three-dimensional descriptive data of craniofacial structural changes.
Related Concept Videos
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Measurement: Standard Units
Measurement: Derived Units
Inertial Frames of Reference
Non-inertial Frames of Reference
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...