Related Experiment Video
Updated: Feb 1, 2026

An Experimental Platform to Study the Closed-loop Performance of Brain-machine Interfaces
Published on: March 10, 2011
Double-row 18-loop transceive-32-loop receive tight-fit array provides for whole-brain coverage, high transmit
Nikolai I Avdievich1, Ioannis-Angelos Giapitzakis1,2, Jonas Bause1,2
1High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.
Purpose:
To improve the transmit (Tx) and receive (Rx) performance of a human head array and provide whole-brain coverage at 9.4T, a novel 32-element array design was developed, constructed, and tested.
Methods:
The array consists of 18 transceiver (TxRx) surface loops and 14 Rx-only vertical loops all placed in a single layer. The new design combines benefits of both TxRx and transmit-only-receive-only (ToRo) designs. The general idea of the design is that the total number of array elements (both TxRx and Rx) should not exceed the number of required Rx elements. First, the necessary number of TxRx loops is placed around the object tightly to optimize the Tx performance. The rest of the elements are loops, which are used only for reception. We also compared the performance of the new array with that of a state-of-the-art ToRo array consisting of 16 Tx-only loops and 31 Rx-only loops.
Results:
The new array provides whole-brain coverage, ~1.5 times greater Tx efficiency and 1.3 times higher SNR near the brain center as compared to the ToRo array, while the latter delivers higher (up to 1.5 times) peripheral SNR.
Conclusion:
In general, the new approach of constructing a single-layer array consisting of both TxRx- and Rx-only elements simplifies the array construction by minimizing the total number of elements and makes the entire design more robust and, therefore, safe. Overall, our work provides a recipe for a Tx- and Rx-efficient head array coil suitable for parallel transmission and reception as well as whole-brain imaging at UHF.
Related Concept Videos
Feedback Loops
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Positive and Negative Feedback Loops
Cell Signaling Feedback Loops
Negative feedback loops
Most signaling systems have negative feedback loops that can perform different functions such as output limiter, and adaptation.
Output limiter
Upon receiving an input signal, the cellular response rapidly increases until a threshold is reached. Beyond this threshold, a negative feedback loop...
Magnetic Field Of A Current Loop
Reabsorption and Secretion in the Loop of Henle

