Control of Lead Sources in the United States, 1970-2017: Public Health Progress and Current Challenges to Eliminating

Timothy Dignam1, Rachel B Kaufmann, Lauren LeStourgeon

  • 1Lead Poisoning Prevention and Environmental Health Tracking Branch (Dr Dignam) and National Center for Chronic Disease Prevention and Health Promotion (Dr Kaufmann), Centers for Disease Control and Prevention, Atlanta, Georgia; Department of Environmental Health, Rollins School of Public Health, Emory University, Atlanta, Georgia (Ms LeStourgeon); and Department of Social and Behavioral Sciences, Harvard T. H. Chan School of Public Health, Cambridge, Massachusetts (Dr Brown).

Abstract

Related Concept Videos

Phase-lead and Phase-lag Controllers01:22

Phase-lead and Phase-lag Controllers

Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
546
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
454
Mesh Analysis with Current Sources01:10

Mesh Analysis with Current Sources

Mesh analysis becomes simpler when analyzing circuits with current sources, whether independent or dependent. The presence of current sources reduces the number of equations required for analysis. Two cases illustrate this:
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
2.0K
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
705
Controlled-Current Coulometry: Coulometric Titration01:18

Controlled-Current Coulometry: Coulometric Titration

Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
549
Measurement: Derived Units03:02

Measurement: Derived Units

The International System of Units or SI system, by international agreement, has fixed measurement units for seven fundamental properties: length, mass, time, temperature, electric current, amount of substance, and luminosity. These are called the SI base units.
55.4K