Reattachment of the flexor and extensor tendons at the epicondyle in elbow instability: a biomechanical comparison of
Andreas Lenich1, Christian Pfeifer2, Philipp Proier3
1Helios Clinic Munich West, Department of Orthopedic Sports Medicine, Trauma Surgery and Hand Surgery, Steinerweg 5, 81241, Munich, Germany.
Background:
Elbow dislocation represents a common injury, especially in the younger population. If treated surgically, the reattached tendons require a high amount of primary stability to allow for an early rehabilitation to avoid postoperative stiffness. The purpose of this study was to assess the biomechanical properties of a single and a double row technique for reattachment of the common extensor and common flexor muscles origin. We hypothesized that the double row technique would provide greater stability in terms of pullout forces than the single row technique.
Methods:
Twelve cadaveric specimens were randomized into two groups of fixation methods for the common extensor tendon or the common flexor tendon at the elbow (1): a single row technique using two knotted 3.0 mm suture anchors, and (2) a double row technique using an additional knotless 3.5 mm anchor. The repairs were cyclically loaded over 500 cycles at 1 Hz from 10 N to a maximum of 100 N (extensors) or 150 N (flexors), and then pulled to failure. Stiffness and maximum load at failure and mode of failure were recorded and calculated.
Results:
No significant differences in stiffness were observed between the two techniques for both the extensor and flexor reattachment (P = 0.701 and P = 0.306, respectively). The mean maximum load at failure indicated that the double row construct was significantly stronger than the single row construct. This was found to be true for both the extensor and flexor reattachment (213.6; SD 78.7 N versus 384.1; SD 105.6 N, P = 0.010 and 203.7; SD 65.8 N versus 318.0; SD 64.6 N, P = 0.013, respectively).
Conclusions:
The double row technique provides significant greater stability to the reattached common flexor or extensor origin to the medial or lateral epicondyle. Thus, it should be considered in the development of improved repair techniques for stabilizers of the elbow.
Study Design:
Controlled laboratory study.
Related Concept Videos
Microtubule Instability
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits