Ureteral Rupture Caused by Accidental Intubation of the Ureter with a Foley-Catheter during Ureterorenoscopy
F Löcherbach1, P Grimsehl1, A Sauer1
1Cantonal Hospital Aarau, Aarau, Switzerland.
Abstract:
We would like to present the case of a 64-year-old woman who underwent ureterorenoscopy and suffered an iatrogenic ureteral lesion due to an accidental intubation of the left ureter with a Foley-Catheter during the procedure. A Double-J-Stent was implanted into the damaged ureter, and 6 weeks later it fully recovered. To our knowledge there are few similar cases described in the literature with none of those having happened during ureterorenoscopy so far.
More Related Videos
10:39Single Cell Measurements of Vacuolar Rupture Caused by Intracellular Pathogens
Published on: June 12, 2013
06:39Technical Modification of the Terminal Ureter During Total Transperitoneal Laparoscopic Nephroureterectomy for Upper Urinary Tract Urothelial Carcinoma
Published on: November 22, 2019
Related Concept Videos
Ureters
Anatomy of the Genitourinary System I: Kidneys and Ureters
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Osmosis and Osmotic Pressure of Solutions