Related Experiment Video
Updated: Feb 1, 2026

Endotracheal Intubation of Rabbits Using a Polypropylene Guide Catheter
Published on: November 13, 2017
Single lumen endotracheal intubation with carbon dioxide insufflation for lung isolation in thoracic surgery
Raul Caso1, Colleen Hamm Kelly2, M Blair Marshall3
1Division of Thoracic Surgery, Department of Surgery, MedStar Georgetown University Hospital, 3800 Reservoir Rd, NW, Washington, DC, 20007, USA. Raul.Caso@gunet.georgetown.edu.
Introduction:
Double lumen tube (DLT) intubation is used for lung isolation but is not without disadvantages including increased intubation time, anesthesia expertise, risk of airway trauma, and costs over single lumen tube (SLT) intubation. SLT intubation with CO2 insufflation can be used as an alternative for lung isolation. We reviewed our experience with this technique during thoracoscopic surgery.
Methods:
We performed a retrospective review of a prospectively maintained IRB-approved database from 2009 to 2018. Operations were performed with CO2 insufflation up to 15 mmHg. Indications for surgery, operative details, intraoperative complications, pathology, and postoperative complications were reviewed.
Results:
We identified 123 patients (70 females [57%]) with a median age of 40 years (range 16-80 years) and a median BMI of 26.2 kg/m2 (range 15-59 kg/m2) that underwent minimally invasive thoracoscopic procedures with this technique. Procedures included: mediastinal mass resection or biopsy (41%), sympathectomy (37%), wedge resection (10%), first rib resection (6%), diaphragm plication (2%), segmentectomy (2%), decortication (2%), pleural biopsy (2%), and pericardial cyst resection (1%). Median operative time was 90 min (range 25-584 min) and median intraoperative blood loss was 10 mL (range 2-200 mL). Intraoperative hemodynamic parameters were obtained at procedure start, 1 h after CO2 insufflation, and at procedure completion: we observed significant changes in heart rate and systolic blood pressure (P = 0.027 and P < 0.001, respectively) although clinically inconsequential. Mean end-tidal CO2 1 h after insufflation was 36.6 ± 4.5 mmHg. There were no intraoperative complications and no conversions to a DLT. Median length of stay was 1 day (range 0-14 days). Five complications (4%) were observed and no mortalities.
Conclusions:
SLT intubation and CO2 insufflation is a feasible and safe alternative to DLT intubation for lung isolation. This can be a useful strategy to accomplish lung isolation for some thoracoscopic procedures, in particular when expertise for DLT placement is unavailable.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Carbon-dioxide Fixation
Carbon Dioxide Transport in the Blood
Forms of CO2 Transport
1. Dissolved in plasma: A small percentage (7-10%) of CO2 is transported and dissolved directly in the plasma.
2. Carbaminohemoglobin: Just over 20% of CO2 is chemically bound to...
The Carbon Cycle
Carbon Skeletons