Blood pressure variability in surgical and intensive care patients: Is there a potential for closed-loop vasopressor
Joseph Rinehart1, Michael Ma1, Michael David Calderon1
1Department of anesthesiology and perioperative care, university of California Irvine, Orange, 101, the City drive South, California, USA.
Abstract:
Blood pressure management in the operating rooms (OR) and intensive care units (ICU) frequently involves manually titrated vasopressor therapy to an optimal range of mean arterial pressure (MAP). Ideally, changes in vasopressor infusion rates have to quickly follow variations in blood pressure measurements. However, such a tightly controlled feedback loop is difficult to achieve. Few studies have examined blood pressure control when vasopressor therapy is administered manually in OR and ICU patients. We extracted MAP data from 3623 patients (2530 from the ORs and 1093 from the ICU) on vasopressors from our electronic medical records. Coefficient of variation (= standard deviation/mean value) *100) was calculated and the values were additionally categorized into different MAP ranges (MAP < 60 mmHg, 60 < MAP < 80 and MAP > 80 mmHg). There was no statistically significant difference between both centres for MAP across all time points (80 ± 12 vs. 80 ± 16, P = 0.996, 95% CI -6 to 6). The coefficients of variation of MAP were 13.7 ± 5.4% and 18.4 ± 9.8% in the OR and in ICU respectively. Patients on vasopressors spent 48.8% treatment time with a MAP between 60 and 80 mmHg (11.2% time with MAP < 60 mmHg, and 40% with MAP > 80 mmHg). These results provide a reasonable baseline from which to establish whether 'reduced variability' may be achieved with a closed-loop vasopressor administration system.
More Related Videos
Related Concept Videos
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Intensity and Pressure of Sound Waves
Unlike the time average of a sinusoidal term, which is zero since it is positive...
Patient-centered Care
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...