Related Experiment Video
Updated: Feb 1, 2026

Imaging Features of Systemic Sclerosis-Associated Interstitial Lung Disease
Published on: June 16, 2020
The place of high-resolution computed tomography imaging in the investigation of interstitial lung disease
Florence Jeny1,2, Pierre-Yves Brillet2,3, Young-Wouk Kim3
1a Université Paris 13, EA2363 "Hypoxie & Poumon" , Sorbonne-Paris-Cité , Bobigny, France.
Introduction:
High-resolution computed tomography (HRCT) has revolutionized the diagnosis, prognosis and in some cases the prediction of therapeutic response in interstitial lung disease (ILD). HRCT represents an essential second step to a patient's clinical history, before considering any other investigation, including lung biopsy. Areas covered: This review describes the current place of HRCT in the diagnosis, prognosis and monitoring of ILD. It also lists some perspectives for the near future. Expert commentary: Since the 1980s, HRCT and its interpretation have improved, the diagnosis value of patterns, and the integration of bio-clinical elements to HRCT have been better standardized. The interobserver agreement has been investigated, allowing a better use of some limits in the interpretation of various signs. It not only takes into account one particular predominant sign, but the combination of patterns and the distribution of findings. Thanks to HRCT, the range of diagnoses and their probability are more accurately identified. The contribution of HRCT has been optimized during the multidisciplinary discussion that a difficult diagnosis calls for. HRCT quantification of the extent of diffuse lung disease becomes possible and is linked to prognosis. In the future, artificial intelligence may significantly modify the practice of radiology.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Lung Capacity
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Design Example: Traverse Angle Computations
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.