Related Experiment Video
Updated: Feb 1, 2026

Author Spotlight: Unveiling the Connection Between Sleep Disorders and Cognitive Symptoms in Depression
Published on: April 26, 2024
Has the quality of physiotherapy care in patients with Whiplash-associated disorders (WAD) improved over time? A
Rob Ab Oostendorp1,2,3,4, Hans Elvers5,6, Emiel van Trijffel7,8
1Scientific Institute for Quality of Healthcare, Radboud University Nijmegen Medical Centre, Nijmegen, the Netherlands, oostendorp.rob@gmail.com.
Purpose:
To develop valid quality indicators (QIs) for physiotherapy care based on best available evidence, and to use these QIs to explore trends in the quality of physiotherapy care of patients with Whiplash-associated disorders (WAD) using guideline-based routinely collected data (RCD) gathered between 1996 and 2011.
Materials And Methods:
The study consisted of two phases: 1) development of QIs and 2) analysis of patient records. A set of QIs was developed based on recommendations in the scientific literature and the Dutch Clinical Practice Guideline (CPG) "Physiotherapy Management and WAD". QIs were expressed as percentages, allowing target performance levels to be defined (≥80% or ≤30% depending on whether desired performance required a high or low score on a QI). We then analyzed WAD patient data (N = 810) collected over a period of 16 years in two physiotherapy practices, separating patients into two groups defined as before (Group A 1996-2002; n = 353) and after (Group B 2003-2011; n = 457) implementation and transition to the Dutch CPG "Physiotherapy Management and WAD".
Results:
Using an iterative process and input from both experts and users, 28 QIs were developed and subsequently classified per step of the clinical reasoning process for physiotherapy care. Based on 16 years of RCD, we found that the clinical reasoning process differed significantly (P ≤ 0.05) between the groups, in favor of Group B. Twelve of the 25 indicators (48.0%) in Group A and 19 of 26 indicators (73.1%) in Group B met predetermined performance targets. The number of target indicators also differed significantly between groups, favoring Group B (P ≤ 0.05).
Conclusion:
A preliminary set of novel QIs was developed. Using RCD and these QIs, we conclude that physiotherapy care in our study setting improved over the period 1996-2011. Furthermore, the QIs met the performance targets set for the clinical reasoning process after the transition to the Dutch CPG "Physiotherapy Management and WAD".
Related Concept Videos
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Quality Assurance
Quality of Water
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Testing Water Quality
Data Collection II

