Related Experiment Video
Updated: Feb 1, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Minimally invasive plate osteosynthesis (MIPO) in AO/OTA type B displaced clavicle fractures
R S Kundangar1, S P Mohanty2, N S Bhat2
1Department of Orthopaedics, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, 576104, India. raghurajsk74@gmail.com.
Introduction:
Open reduction and plate fixation is known to reduce chances of malunion and symptomatic nonunion in displaced middle-third clavicle fractures. However, this treatment modality is also associated with several complications, such as hardware irritation, numbness around the surgical scar, infection, nonunion and implant failure. The minimally invasive plate osteosynthesis (MIPO) technique may reduce these complications.
Objective:
To study clinical, radiological and functional outcomes of MIPO in AO/OTA type B displaced clavicle fractures and report any complications.
Materials And Methods:
A total of 22 patients underwent internal fixation of acute displaced AO/OTA type B clavicle fractures from Jan 2014 to Dec 2015 by MIPO using locking compression plates. Patients were followed up at a regular interval and assessed clinically and radiologically. The clavicle length difference was measured. Functional assessment was done at the end of 2 year using constant shoulder score (CSS) and disability of the arm, shoulder and hand score (Quick DASH) and complications if any were noted.
Results:
All fractures united at a mean of 12.5 weeks. One (4.5%) patient had numbness around the surgical scar. None of the patients had wound-related complications. In four patients, hardware irritation was noted. The difference in clavicle length was not significant. All patients had excellent CSS and Quick DASH score at the final follow-up.
Conclusion:
Internal fixation of displaced AO/OTA type B clavicle fractures by MIPO showed high fracture union rates and good functional outcomes.
Related Concept Videos
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Displacement Current
Position and Displacement
Position and Displacement Vectors
Further, several important kinds of...
Significance of Displacement Current
Angular Velocity and Displacement