Related Experiment Video
Updated: Feb 1, 2026

Epitaxial Growth of Perovskite Strontium Titanate on Germanium via Atomic Layer Deposition
Published on: July 26, 2016
Effect of a Simulation of 241Am Deposition Pattern in the Leg Bones on the Detection Efficiency of a High Purity
Abstract:
A computational model using an MCNPX version 2.6.0 code and a leg voxel phantom was previously constructed and validated against the in vivo measurements of the United States Transuranium and Uranium Registries (USTUR) case 0846 leg. Using the MCNPX model, different simulation scenarios of Am distribution in the bones and tissue material of a leg were performed, and their effects on the detection efficiency and activity calculation were examined. The purpose of this work is to ensure and increase the simulation sensitivity of real contaminated human bones and reduce the simulated efficiency error associated with the distribution of Am activity within the leg bones when using a high purity germanium [HP(Ge)] detector. The results showed that the simulated detection efficiency obtained from the uniform distribution of Am in the leg bones was underestimated by a factor of up to 0.3 compared with the measured and simulated detection efficiency obtained from the non-uniform distribution of Am in different sections of the leg bones. The p-value of a one-way analysis of variance (ANOVA) F-test among the mean values of the simulated detection efficiencies was calculated and provided evidence of a significant difference. The uncertainty in the bone activity estimate could be quite large (25% to 30%) if calibration of detection efficiency is based on assuming a uniform distribution of Am in the phantom to estimate the USTUR case 0846 leg activity. It is therefore recommended that during calibration of detectors, a non-uniform distribution of Am in different sections of the bones should be used rather than a uniform distribution. Additionally, an assumption of a uniform distribution of Am will simulate Am activity deposited in the leg bones of a real contamination case inadequately.
Related Concept Videos
Muscles that Move the Leg
Anterior Compartment
The quadriceps femoris, the most visible muscle of the anterior compartment, is integral for leg extension and thigh flexion. It is formed by merging four distinct muscles — the vastus lateralis, vastus medialis, vastus intermedius, and rectus femoris. The quadriceps tendon, a shared tendon of the four quadriceps muscles, is affixed...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Phase Transitions: Sublimation and Deposition
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Fixed Action Patterns

