Related Experiment Video
Updated: Feb 1, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
A feasibility study of spatiotemporally integrated radiotherapy using the LQ model
1Radiation Oncology, University of Washington Seattle, Washington, DC, United States of America.
Abstract:
This paper investigates the feasibility of spatiotemporally modulated radiotherapy (STMRT)-integrated model with explicit constraints on the tumor dose heterogeneity. In particular, we demonstrate the effect of the tumor dose heterogeneity on the tumor biologically effective dose (BED) achievable and optimal fractionation. We propose an STMRT model that simultaneously optimizes the dose distributions and fractionation schedule for each individual case with the maximum and minimum constraints on the tumor BED to explicitly control the level of tumor dose heterogeneity. Sixteen thoracic phantom cases were planned using (1) STMRT and (2) standard fractionation (60 Gy in 30 fractions fixed) IMRT. Constraints on the organs-at-risk (OAR) BED were identical for both plans. BEDs were calculated using the [Formula: see text] ratio of 10 Gy for the tumor and 3 Gy for all OARs. The maximum tumor BED for STMRT plans was constrained to be less than 100%-150% of the maximum tumor BED resulted from the standard fractionation plans. The mean tumor BED from STMRT plans was up to 110.7%, 128.3%, 135.0% and 148.0% of that from the standard fractionation plans when the maximum tumor BED was constrained to be less than 100%, 120%, 130% and 150% of the maximum BED achieved using the standard plans. The optimal number of fractions varied widely for different phantom geometries for the same radiobiological parameter values. The increase in the tumor BED and the range of optimal fractionation was larger with a larger tumor dose heterogeneity allowed. The results have shown the feasibility of personalizing fractionation schedule using an STMRT integrated model to deliver a maximum feasible BED to the tumor for a fixed OAR BED. The potential increase in the tumor BED was positively correlated to the tumor dose heterogeneity allowed.
Related Concept Videos
Growth Models with Integration: Problem Solving
Integration by Parts: Indefinite Integrals
Integration by Parts: Definite Integrals
Typical Model Studies
The Integrated Rate Law: The Dependence of Concentration on Time
Integrator and Differentiator
An integrator within an op-amp circuit produces an output directly proportional to the integral of the input signal. This is achieved by replacing the feedback resistor in a typical inverting...

