Statistical weights for model-based reconstruction in cone-beam CT with electronic noise and dual-gain detector
P Wu1, J W Stayman1, A Sisniega1
1Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, United States of America.
Abstract:
Cone-beam CT (CBCT) systems commonly incorporate a flat-panel detector (FPD) with multiple-gain readout capability to reduce electronic noise and extend dynamic range. In this work, we report a penalized weighted least-squares (PWLS) method for CBCT image reconstruction with a system model that includes the electronic noise characteristics of FPDs, including systems with dynamic-gain or dual-gain (DG) readout in which the electronic noise is spatially varying. Statistical weights in PWLS were modified to account for the contribution of the electronic noise (algorithm denoted [Formula: see text]), and the method was combined with a certainty-based approach that improves the homogeneity of spatial resolution (algorithm denoted [Formula: see text]). The methods were tested in phantom studies designed to stress DG readout characteristics and translated to a clinical study for CBCT of patients with head traumas. The [Formula: see text] method demonstrated superior noise-resolution tradeoffs compared to filtered back-projection (FBP) and conventional PWLS. For example, with spatial resolution (edge-spread function width) matched at 0.65 mm, [Formula: see text] reduced variance by 28%-39% and 15%-25% compared to FBP and PWLS, respectively. The [Formula: see text] method achieved more homogeneous spatial resolution than [Formula: see text] while maintaining similar variance reduction. These findings were confirmed in clinical studies, which showed ~20% variance reduction in peripheral regions of the brain, potentially improving visual image quality in detection of epidural and/or subdural intracranial hemorrhage. The results are consistent with the general notion that incorporating a more accurate system model improves performance in optimization-based statistical CBCT reconstruction-in this case, a more accurate model for (spatially varying) electronic noise to improve detectability of low-contrast lesions.
More Related Videos
Related Concept Videos
Electron Orbital Model
The first shell is closest to the nucleus, and it has only one subshell with a single spherical orbital called the...
Statistical Significance
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Gain
Gain:
Suppose Vin is the input and Vout is the output signal to a circuit.
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...