Related Experiment Video
Updated: Feb 1, 2026

A Novel Murine Model of Arteriovenous Fistula Failure: The Surgical Procedure in Detail
Published on: February 3, 2016
Hemodynamic effects of hemodialyzer pump speed on arteriovenous fistulas
Aim:
Arteriovenous fistulas (AVF) are the optimal vascular access for hemodialysis although many fistulas fail. The impetus to increase hemodialyzer blood flow (QB) in order to maximize solute clearances may be counterbalanced if AVF suffer adverse hemodynamic effects from accelerated pump flows. The optimal QB to maintain adequate hemodialysis without potentially contributing to AVF dysfunction is unknown. The aim of this study was to measure the hemodynamic effects of increased QB on AVF.
Materials And Methods:
A prospective cohort of 14 patients with primary brachiocephalic AVF underwent venous Doppler measurements prior to cannulation (QB0) and during hemodialysis with QB of 350 mL/min at a standardized anatomical location over 3 - 16 consecutive months. Measurements included vein diameter, blood flow velocity, and volumetric flow.
Results:
163 paired Doppler measurements (QB0 and QB350) were made in 14 subjects. There were no significant differences in venous diameter, but significant increases in blood flow velocity and volumetric flow (p < 0.001). Mean blood flow velocity increased from 86.6 ± 35.0 cm/s at QB0 to 105.7 ± 35.0 cm/s at QB350. Mean volumetric flow increased from 849 mL/min at QB0 to 1,059 mL/min at QB350. Vein diameters increased linearly over time, with no significant changes in blood velocity or volumetric flow, suggesting AVF maturation may improve tolerance of pumped blood flow.
Conclusion:
Blood flow velocity and volumetric flow increased when hemodialyzer blood pump was applied to an AVF, creating a situation in which increased turbulence and shear stress might be plausible. Further study is needed to determine if increased QB affects clinical outcomes of AVF. .
Related Concept Videos
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Speed of Sound in Gases
Speed of a Transverse Wave
One of the key properties of any wave is the wave speed. Light...