Related Experiment Video
Updated: Feb 1, 2026

Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
Comprehensive and Integrative Experimentation Setup for Large Animal Hybrid Valvular Heart Surgery
Mohamed Alaa1, Maria Tsopanomichalou Gklotsou1, Thang Duc Vu1
1Department of Cardiac, Thoracic and Vascular Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.
Background:
Experimental surgical procedures for atrioventricular valves present promising translational capabilities, and preclinical studies are necessary to assess their applicability and to train young enthusiastic heart teams. Here, we present a synopsis of experimental surgical procedures on porcine models for mitral valvular (MV) and tricuspid valvular (TV) interventions; mitral valve-in-valve implantation (MViV), transapical cardioscopic (TAC) MV replacement (MVR), TAC-MV annuloplasty, and tricuspid valve-in-a-ring (TViR) procedures.
Methods:
Twenty-five (n = 25) female Yorkshire pigs of 55-65 kg is the total number used in the four approaches; seven animals underwent MViV, six TAC-MVR, six TAC-MV annuloplasty, and six TViR, respectively. All were subjected to a first conventional valvular surgery (bioprosthetic valve replacement and/or prosthetic ring repair). Then, after 4 wk, a less-invasive second surgery was performed using the transcatheter approaches under investigation. Except for the TAC-MVR and annuloplasty procedures, all animals were followed up for additional 4 wk.
Results:
(1) MViV (n = 7): Standard MVR was successfully performed in all animals. Transvalvular pressure gradients and flow velocities were (Pmax 3.77 ± 0.8 mmHg; Pmean 2.1 ± 0.6 mmHg, Vmax 97 ± 13 cm/s; Vmean 68 ± 21 cm/s). Effective MViV followed (Pmax 16.7 ± 1.8 mmHg; Pmean 6.2 ± 1.2 mmHg, Vmax 216 ± 32 cm/s; Vmean 110 ± 24 cm/s). (2) TAC-MVR (n = 6): The overall bypass time was 177.2 ± 44.2 min. Transprosthetic Pmean was 4.6 ± 2.4 mmHg; no paravalvular leaks in all animals. (3) TAC-MV annuloplasty (n = 6): The implantation time was 47 ± 6 min. MV was competent, left ventricular ejection fraction (LV-EF%) was 63 ± 4%. (4) TViR (n = 6): Conventional TV ring repair was performed in all animals (Pmax 2.42 ± 0.7 mmHg; Pmean 1.3 ± 0.6 mmHg, Vmax 82 ± 10.4 cm/s; Vmean 65.4 ± 21 cm/s). All TViRs were implanted efficiently (Pmax 4.7 ± 1.6 mmHg; Pmean 2.7 ± 0.8 mmHg, Vmax 105 ± 31 cm/s; Vmean 81 ± 16 cm/s). A mild paravalvular leak was observed in one animal (16%).
Conclusions:
All studied experimental valvular interventions are feasible, within the context of well-trained cardiac surgery specialists, and all possibilities should be considered when treating a patient to determine which one suits best his individual challenges and scope.
Related Concept Videos
Hybrid Zones
Hybridization of Atomic Orbitals I
Hybridization of Atomic Orbitals II
Anatomy of the Heart
Integration by Parts: Indefinite Integrals
Integration by Parts: Definite Integrals