Related Experiment Video
Updated: Feb 1, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Prospective Evaluation for Hypoattenuated Leaflet Thickening Following Transcatheter Aortic Valve Implantation
Liang Tang1, John R Lesser2, Lynelle M Schneider2
1Valve Science Center, Minneapolis Heart Institute Foundation, Abbott Northwestern Hospital, Minneapolis, Minnesota; Department of Cardiology, The Second Xiangya Hospital of Central South University, Changsha, China.
Abstract:
Prospective investigations for the frequency of hypoattenuated leaflet thickening (HALT) and its clinical implications in transcatheter aortic valve implantation (TAVI) patients are limited. We initiated a prospective screening program of TAVI patients for HALT beginning in July 2015. Eligible patients were evaluated with gated, contrast-enhanced multidetector computed tomography within 30 days of TAVI, and examined for HALT and clinical outcomes. During the study period, 287 patients (81 ± 8 years; 53% men) who underwent TAVI with commercially approved devices were examined. Overall, 26 patients (9.1%) had occurrence of HALT, and only one of these patients had detectable hemodynamic changes on echocardiography at diagnosis. Notably, 9 of 26 HALT patients had been receiving warfarin, however, the HALT patients more often had subtherapeutic international normalized ratio whereas using warfarin than patients without HALT on index multidetector computed tomography imaging (p = 0.01). Patients who developed HALT had lower baseline aortic gradient, valvuloarterial impedance, and peak aortic velocity, and more commonly had been treated with balloon-expandable valves (73% of all HALT cases) with a higher incidence among those who received larger prostheses. All patients with HALT were placed on anticoagulation at diagnosis, and valvular function remained unchanged at follow-up. Two patients with HALT (7.7%) experienced ischemic stroke. A statistical trend for more major adverse clinical events was present in HALT patients. In conclusion, HALT was detected in 9% of TAVI cases in this prospective observational cohort, with a greater frequency in patients with large, balloon-expandable prostheses. Prospective screening may be considered as early HALT is reversible by timely therapeutic anticoagulation.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Aortic Regurgitation I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Aortic Regurgitation III: Medical Management